ISSN 1004-4140
CN 11-3017/P
WANG Lin-yuan, TONG Li, YAN Bin, HU Guo-en. A Method for Image Bipolar Detail Decomposition Based on the TV/L2 Model[J]. CT Theory and Applications, 2013, 22(1): 75-83.
Citation: WANG Lin-yuan, TONG Li, YAN Bin, HU Guo-en. A Method for Image Bipolar Detail Decomposition Based on the TV/L2 Model[J]. CT Theory and Applications, 2013, 22(1): 75-83.

A Method for Image Bipolar Detail Decomposition Based on the TV/L2 Model

More Information
  • Received Date: September 10, 2012
  • Available Online: December 12, 2022
  • The Total Variation (TV) minimization method based on TV/L2 model is affected by the regularized parameter in image decomposition, This paper suggests that when the value of the chosen regularized parameter is small and different from classic methods, the property of the decomposed image will have an important change. According to this, a new method for image bipolar detail decomposition based on the TV/L2 model is proposed in this paper. The new method can decompose an image into an approximate image and two detailed images with different properties, when the value of the regularized parameter is small. Applying the decomposition model to Printed Circuit Board (PCB) CT images, we found that by combining the information in the detailed images, an enhanced image with metallic artifacts being effectively reduced can be acquired.
  • Related Articles

    [1]SU Danyang, HOU Ping, ZHANG Haoran, MA Yuanbo, LIU Jinlong, YANG Xiaopeng. Research Progress on Reducing Metal Artifacts in CT Imaging[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.023
    [2]HU Yongzhi, WU Pengfei, CAO Da, WANG Binbin, TANG Yuxia, WANG Shouju, WANG Chuanbing. Elucidation of the Efficacy of Low Tube Voltage Combined with AIIR in Suppressing Hip Prosthesis CT Artifacts[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.334
    [3]CHEN Zonggui, WEI Ningning, LI Zhoufan, PAN Guihong, HUANG Minjiang. Methods Research on Correction for Intracranial Metal Artifacts Based on Prior Image Utilization[J]. CT Theory and Applications, 2025, 34(1): 141-148. DOI: 10.15953/j.ctta.2024.002
    [4]WEI Pengyue, HUANG Xiaoying, WU Tong, GUO Fangkai, GUAN Jing, BAO Yunfeng. Effect of denture materials on CT image artifacts: phantom experiment[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.339
    [5]ZUO Shunji, FENG Peng, HUANG Pan, YAN Shenghao, HE Peng, WEI Biao. Metal Artifact Reduction Algorithm for CT Images of Rock and Mineral Samples Based on Dual-domain Adaptive Network[J]. CT Theory and Applications, 2022, 31(6): 783-792. DOI: 10.15953/j.ctta.2022.041
    [6]ZHAO Qingqing, SUN Xiaoli, LI Xi, WANG Yanwen, LIU Weina, DUAN Yongli, WANG Rengui. Utility of Spectral CT Monochromatic Imaging with Metal Artifacts Reduction (MAR) for the Reduction of Metal Artifacts of Embolization Coil Implants[J]. CT Theory and Applications, 2019, 28(5): 529-539. DOI: 10.15953/j.1004-4140.2019.28.05.02
    [7]ZHANG Xue-song, ZHAO Bo-shan. Cupping Artifacts Calibration in CT Image Based on Radon Transform[J]. CT Theory and Applications, 2016, 25(5): 539-546. DOI: 10.15953/j.1004-4140.2016.25.05.05
    [8]CHAI Jia-bin, LI Gong-ping, WEI Cun-feng, WEI Long, YU Yang, WANG Qian, LIU Bao-dong. Metal Artifacts Correction Method Research about Liquid Metal Angiography[J]. CT Theory and Applications, 2016, 25(2): 149-157. DOI: 10.15953/j.1004-4140.2016.25.02.04
    [9]LI Qing-liang, YAN Bin, SUN Hong-sheng, LI Lei, ZHANG Feng. Review of Metal Artifacts Correction Methods on X-ray Computed Tomography[J]. CT Theory and Applications, 2011, 20(1): 131-140.
    [10]GU Jian-wei, ZHANG Li, CHEN Zhi-qiang, XING Yu-xiang, GAO He-wei. The Review of Reasons and Correction Methods for Artifacts in ICT Images[J]. CT Theory and Applications, 2005, 14(3): 24-28.

Catalog

    Article views (1323) PDF downloads (5) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return