The Review of Reasons and Correction Methods for Artifacts in ICT Images

More Information
  • Received Date: June 17, 2005
  • Available Online: December 28, 2022
  • X-ray CT plays a great role in industrial non-destructive tests, medical fields, and public security, etc. In practice the reconstructed images have different kinds of artifacts. In this paper, kinds of reasons and correction methods of artifacts are summarized. Additionally, some comparison and discussion on these methods in recent literatures is done.
  • Related Articles

    [1]CHEN Zonggui, WEI Ningning, LI Zhoufan, PAN Guihong, HUANG Minjiang. Methods Research on Correction for Intracranial Metal Artifacts Based on Prior Image Utilization[J]. CT Theory and Applications, 2025, 34(1): 141-148. DOI: 10.15953/j.ctta.2024.002
    [2]LIU Bicheng, YI Xi, ZONG Chunguang, XU Yanwei, LI Liang. Ring-artifact Correction Method for Large-size Object CT Images Based on Gradient Featured Cluster Analysis[J]. CT Theory and Applications, 2024, 33(6): 781-789. DOI: 10.15953/j.ctta.2024.153
    [3]ZHANG Wenjun, HUANG Gang, DING Haining, XU Hongchun. Research Progress of Scattering Artifact Correction in Medical Cone-beam Computed Tomography Imaging Based on Deep Learning[J]. CT Theory and Applications, 2023, 32(2): 285-296. DOI: 10.15953/j.ctta.2022.131
    [4]ZUO Shunji, FENG Peng, HUANG Pan, YAN Shenghao, HE Peng, WEI Biao. Metal Artifact Reduction Algorithm for CT Images of Rock and Mineral Samples Based on Dual-domain Adaptive Network[J]. CT Theory and Applications, 2022, 31(6): 783-792. DOI: 10.15953/j.ctta.2022.041
    [5]LUO Chen, REN Qing, LIU Jianqiang, NIU Tianye. Development of Motion Artifact Correction Solutions for the Cone-beam CT Images during Pancreatic Cancer Image-guided Radiotherapy[J]. CT Theory and Applications, 2022, 31(6): 761-771. DOI: 10.15953/j.ctta.2022.066
    [6]ZHANG Xue-song, ZHAO Bo-shan. Cupping Artifacts Calibration in CT Image Based on Radon Transform[J]. CT Theory and Applications, 2016, 25(5): 539-546. DOI: 10.15953/j.1004-4140.2016.25.05.05
    [7]CHAI Jia-bin, LI Gong-ping, WEI Cun-feng, WEI Long, YU Yang, WANG Qian, LIU Bao-dong. Metal Artifacts Correction Method Research about Liquid Metal Angiography[J]. CT Theory and Applications, 2016, 25(2): 149-157. DOI: 10.15953/j.1004-4140.2016.25.02.04
    [8]LI Zhong-chuan, MENG Fan-yong, YANG Min. The Correction of Fan-beam CT Image Artifacts Induced by Deflection of Linear-detectors[J]. CT Theory and Applications, 2014, 23(2): 237-248.
    [9]WANG Xue-li. Medical CT Artifact Analysis: Reason and Correction[J]. CT Theory and Applications, 2004, 13(3): 1-8.
    [10]Zu Donglin, He Qiang, Luo Qingfei, Jin Zhen, Bao Shanglian. The Correction of Motion Artifact with fMRI Using Image Registration[J]. CT Theory and Applications, 2001, 10(4): 1-3.

Catalog

    Article views (1040) PDF downloads (56) Cited by()