ISSN 1004-4140
CN 11-3017/P
Zu Donglin, He Qiang, Luo Qingfei, Jin Zhen, Bao Shanglian. The Correction of Motion Artifact with fMRI Using Image Registration[J]. CT Theory and Applications, 2001, 10(4): 1-3.
Citation: Zu Donglin, He Qiang, Luo Qingfei, Jin Zhen, Bao Shanglian. The Correction of Motion Artifact with fMRI Using Image Registration[J]. CT Theory and Applications, 2001, 10(4): 1-3.

The Correction of Motion Artifact with fMRI Using Image Registration

More Information
  • Received Date: September 27, 2001
  • Available Online: December 28, 2022
  • We consider human head as a rigid body, so the six parameters(3 of translation, 3 of rotation) that describe rigid body transformation can be applied to image registration. At first, the six parameters are given an initial value respectively. Then, they are optimized iteratively. The most optimized parameters are determined when we get the sum of squared differences between source image(the image to be registered) and reference image. After the acusector sting fMRI images are processed by 3D registration, most motion artifact can be eliminated, and the effect is satisfied.
  • Related Articles

    [1]CAO Jiasheng, LI Baolei. Analysis of Accuracy Related Factors in Photon Counting X-ray CT Energy Imaging[J]. CT Theory and Applications, 2025, 34(2): 255-262. DOI: 10.15953/j.ctta.2024.254
    [2]WANG Ce, ZHOU Fengyun, XUAN Yanjiao, WANG Wenhai, YAO Lin, SHI Zheng, MA Yongzhong, CHENG Xiaoguang. Measurement and Analysis of Gonadal Irradiation Dose During Singe-shot X-ray Exposure of Both Lower Limbs[J]. CT Theory and Applications, 2024, 33(5): 627-632. DOI: 10.15953/j.ctta.2023.171
    [3]SUN Guangjiang, YAO Xiaosheng, YANG Dongxiang. Analysis of the Value of Three-dimensional CT and X-ray Examination in Calcaneal Fractures[J]. CT Theory and Applications, 2019, 28(3): 371-376. DOI: 10.15953/j.1004-4140.2019.28.03.11
    [4]FENG Xia, SHI Chao, DING Wen-bo, FENG Yan, HAO Zhen-ping. The Complication of Spectral Analysis Based on Fourier Transform in the Tire X-ray Detection[J]. CT Theory and Applications, 2014, 23(3): 453-458.
    [5]HUO Mei-chun, DONG Guo-ping, LIANG Ze, LI Hao, LIU Dan, GU Dong-bo, MIAO Xiang-yue. Development and Application Analysis of a Tester for X-ray Detectors[J]. CT Theory and Applications, 2012, 21(4): 699-704.
    [6]ZHANG Jun-sheng, WANG Ming-quan, GUO Yong-liang, CHEN Zhi-qiang. Analysis of X-ray Digital Imaging System Resolution[J]. CT Theory and Applications, 2011, 20(2): 227-234.
    [7]HOU Ying, SUN Yi. Analysis on Application of Calibration Method for Cone-beam X-CT[J]. CT Theory and Applications, 2011, 20(2): 211-220.
    [8]ZHU Hua-qiang, LIU Si-run, QIU Jian, LUO Dong-mei, ZHOU De-ming. X-ray and CT Image Analysis of Pelvic Fractures[J]. CT Theory and Applications, 2011, 20(1): 83-90.
    [9]SONG Fu-jing, TONG Jing, JI Zhi-min, ZHANG Bo, JIANG Guo-lin, ZHANG Guang-ping. To Analysis The Chest X-ray Character of SARS[J]. CT Theory and Applications, 2004, 13(2): 33-36.
    [10]WANG Xue-li. Spatial Resolution and Fourier Analysis for X-ray Medical Device[J]. CT Theory and Applications, 2003, 12(4): 36-41.

Catalog