ISSN 1004-4140
CN 11-3017/P
LIU Zhe, ZHANG Li. Review of γ-ray CT for Radioactive Waste Assay[J]. CT Theory and Applications, 2014, 23(6): 1025-1040.
Citation: LIU Zhe, ZHANG Li. Review of γ-ray CT for Radioactive Waste Assay[J]. CT Theory and Applications, 2014, 23(6): 1025-1040.

Review of γ-ray CT for Radioactive Waste Assay

More Information
  • Received Date: April 08, 2014
  • Available Online: December 09, 2022
  • γ-ray CT is one of the non-destructive technologies increasingly applied for radioactive waste assay in recent years. The radioactive sources in the target objects can be identified, quantitified and located by γ-ray CT, offering the bases for further disposal and management of the radioactive waste. In this paper, the application background of γ-ray CT for radioactive waste assay is briefly described, and the mathematical models, system designs of the technology are summarized, as well as its main performance indices and influencing factors. Furthermore, the research developments in key techniques about the algorithms and correction methods for radioactivity image reconstruction are introduced in detail. Finally, an outlook to future developments of the technology is given.
  • Related Articles

    [1]ZHAO Haoxiang, ZHAO Xiaojie, CHEN Ping, WEI Jiaotong. CT Scatter Correction Based on Beam-hole Array and ADMM Algorithm[J]. CT Theory and Applications, 2025, 34(2): 225-234. DOI: 10.15953/j.ctta.2024.236
    [2]SHANG Lei-min, TIAN Li-xia, YUAN Ming-kai, DAI Chao-cheng, LI Lin, HUANG Xian-chao, WEI Cun-feng. Geometric Correction Method for Double-plane “Multi-use” Nuclear Medical Imaging System[J]. CT Theory and Applications, 2017, 26(2): 129-138. DOI: 10.15953/j.1004-4140.2017.26.02.01
    [3]LI Qing-liang, YAN Bin, SUN Hong-sheng, LI Lei, ZHANG Feng. Review of Metal Artifacts Correction Methods on X-ray Computed Tomography[J]. CT Theory and Applications, 2011, 20(1): 131-140.
    [4]CHEN Hui-juan, PAN Jin-xiao. A Beam-Hardening Correction Method Based on Poly-Energetic Statistics in X-Ray CT[J]. CT Theory and Applications, 2010, 19(1): 21-27.
    [5]LIAN Ya-qin, ZHANG Bin, PAN Jin-xiao. An Improved Method of CT Image Hardening Correction Based on Original Projection[J]. CT Theory and Applications, 2009, 18(1): 23-28.
    [6]HU Dong-cai, CHEN Hao, ZHANG Ding-hua. Scatter Correction Method for Flat-Panel Detector-Based Cone Beam CT[J]. CT Theory and Applications, 2009, 18(1): 16-22.
    [7]GU Jian-wei, ZHANG Li, CHEN Zhi-qiang, XING Yu-xiang, GAO He-wei. The Review of Reasons and Correction Methods for Artifacts in ICT Images[J]. CT Theory and Applications, 2005, 14(3): 24-28.
    [8]HAN Yu-sheng, YI Su-jun, SHAO Li-kang, DING Hou-ben, LI Peng-hui, NIE Chao, QIN Xiao-yan. Algorithm of Real-time Image Correction for Multi-speed Security Verification System[J]. CT Theory and Applications, 2003, 12(4): 5-9.
    [9]YE Xia-juan, ZHANG Peng. Estimation of Energy Spectra of CT System And Beam-Hardening Correction Algorithm[J]. CT Theory and Applications, 2003, 12(2): 10-15.
    [10]Ming JIANG, Zao-tian ZHANG. Review on POCS Algorithms for Image Reconstruction[J]. CT Theory and Applications, 2003, 12(1): 51-55.

Catalog

    Article views (755) PDF downloads (9) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return