Optimized Design of X-ray Spectrum Filter for CT

More Information
  • Received Date: May 19, 2011
  • Available Online: December 14, 2022
  • The optimized design of X-ray spectrum filter for computed tomography is studied by Monte Carlo method in this paper. The generation process of X-ray using electron bombardment metal target and the transport process of X-ray through different filters were simulated by EGSnrc software. The formula for optimized design was presented on the basis of signal to noise ratio (SNR). The results show that the optimal parameter for filter design exists, and it is different under different imaging conditions and requirements, which is determined by the actual conditions.
  • Related Articles

    [1]WANG Yongsheng, YANG Leiqing, YANG Yifan, PEI Qingxia, WANG Chensi, LU Mengyun, HE Junlin, CHEN Wenjing, TIAN Xiangbao. The Effect of Different Trigger Thresholds on the Quality of Pulmonary Artery CT Angiography Images[J]. CT Theory and Applications, 2024, 33(2): 175-181. DOI: 10.15953/j.ctta.2023.121
    [2]LIU Fangtao, LIU Heshi, CHEN Yong, JIANG Jiang, WANG Lingyun, DONG Haipeng, ZHANG Yong, ZHANG Xuan, KONG Deyan, CHANG Rui. Image Quality Assessment for Deep Learning Image Reconstruction Algorithm: A Phantom Study[J]. CT Theory and Applications, 2022, 31(3): 351-356. DOI: 10.15953/j.ctta.2021.061
    [3]FANG Shu, CHEN Linyu, CHEN Yong, DONG Haipeng, WANG Lan, MIN Jihua. Phantom Study on the Influence of CT Model and Tube Voltage on Image Quality[J]. CT Theory and Applications, 2022, 31(3): 345-350. DOI: 10.15953/j.ctta.2021.042
    [4]YANG Zhengjun, ZHANG Ang, CHEN Yong, JIANG Jiang, WANG Lingyun, ZHANG Yong, ZHANG Xuan, QI Xiaofeng. The Effect of Radiation Dose and Tube Potential on Image Quality of CT: A Task-based Image Quality Assessment[J]. CT Theory and Applications, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060
    [5]WU Sheng-li, PAN Rui-yi, WEN Bin. Fast Accomplishment of Reconstruction Algorithm for Cone Beam CT[J]. CT Theory and Applications, 2007, 16(4): 31-37.
    [6]SHAO Jun-ming, XU Xiao-dong, KONG Jun. Research on CT System Imaging Quality[J]. CT Theory and Applications, 2006, 15(3): 61-67.
    [7]LI Jian-ying. GEVCT–Harmony Between High Image Quality and Low X-ray Dose[J]. CT Theory and Applications, 2006, 15(3): 57-60.
    [8]WANG Ge, Seung WookLee. Grangeat-Type and Katsevich-Type Algorithms for Cone-Beam CT[J]. CT Theory and Applications, 2003, 12(2): 45-55.
    [9]Zhang Peng, Zhang Zhaotian. Research and Comparison on Several CT Reconstruction Algorithms[J]. CT Theory and Applications, 2001, 10(4): 4-9.
    [10]Guo Lücan, Chen Weichang. The Development of Micro-CT and It's Effect on Making Beauty and Health Improving[J]. CT Theory and Applications, 2001, 10(2): 41-42,18.

Catalog

    Article views (868) PDF downloads (9) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return