ISSN 1004-4140
CN 11-3017/P
LI Zheng-rong, LIU Xiao-ping, LI Zi-yuan, DING Hou-ben. Research of the Method for Multi-threshold Value in Image Segmentation[J]. CT Theory and Applications, 2006, 15(4): 13-17.
Citation: LI Zheng-rong, LIU Xiao-ping, LI Zi-yuan, DING Hou-ben. Research of the Method for Multi-threshold Value in Image Segmentation[J]. CT Theory and Applications, 2006, 15(4): 13-17.

Research of the Method for Multi-threshold Value in Image Segmentation

More Information
  • Received Date: July 07, 2006
  • Available Online: December 16, 2022
  • Objective: The medical image segmentation is the foundation of the follow-up operation,just like 3D reconstruction,...etc.of CT Image.Accuracy of Segmentation is very important to the doctor’s judging.This paper study thoroughly the threshold value segmentation arithmetic and deve-lop a kind of software to solve the medical image multi-threshold value segmentation. Method: This software adopts Visual C++ program tools to carry on a development.It’s function module is mak-ing use of the importation document of the MITK to withdraw and deal with the importation data by the pixel value. Conclusion: Compared with the single threshold value segmentation,Multi-thre-shold value segmentation has many advantages.
  • Related Articles

    [1]WANG Yongsheng, YANG Leiqing, YANG Yifan, PEI Qingxia, WANG Chensi, LU Mengyun, HE Junlin, CHEN Wenjing, TIAN Xiangbao. The Effect of Different Trigger Thresholds on the Quality of Pulmonary Artery CT Angiography Images[J]. CT Theory and Applications, 2024, 33(2): 175-181. DOI: 10.15953/j.ctta.2023.121
    [2]LIU Fangtao, LIU Heshi, CHEN Yong, JIANG Jiang, WANG Lingyun, DONG Haipeng, ZHANG Yong, ZHANG Xuan, KONG Deyan, CHANG Rui. Image Quality Assessment for Deep Learning Image Reconstruction Algorithm: A Phantom Study[J]. CT Theory and Applications, 2022, 31(3): 351-356. DOI: 10.15953/j.ctta.2021.061
    [3]FANG Shu, CHEN Linyu, CHEN Yong, DONG Haipeng, WANG Lan, MIN Jihua. Phantom Study on the Influence of CT Model and Tube Voltage on Image Quality[J]. CT Theory and Applications, 2022, 31(3): 345-350. DOI: 10.15953/j.ctta.2021.042
    [4]YANG Zhengjun, ZHANG Ang, CHEN Yong, JIANG Jiang, WANG Lingyun, ZHANG Yong, ZHANG Xuan, QI Xiaofeng. The Effect of Radiation Dose and Tube Potential on Image Quality of CT: A Task-based Image Quality Assessment[J]. CT Theory and Applications, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060
    [5]WU Sheng-li, PAN Rui-yi, WEN Bin. Fast Accomplishment of Reconstruction Algorithm for Cone Beam CT[J]. CT Theory and Applications, 2007, 16(4): 31-37.
    [6]SHAO Jun-ming, XU Xiao-dong, KONG Jun. Research on CT System Imaging Quality[J]. CT Theory and Applications, 2006, 15(3): 61-67.
    [7]LI Jian-ying. GEVCT–Harmony Between High Image Quality and Low X-ray Dose[J]. CT Theory and Applications, 2006, 15(3): 57-60.
    [8]WANG Ge, Seung WookLee. Grangeat-Type and Katsevich-Type Algorithms for Cone-Beam CT[J]. CT Theory and Applications, 2003, 12(2): 45-55.
    [9]Zhang Peng, Zhang Zhaotian. Research and Comparison on Several CT Reconstruction Algorithms[J]. CT Theory and Applications, 2001, 10(4): 4-9.
    [10]Guo Lücan, Chen Weichang. The Development of Micro-CT and It's Effect on Making Beauty and Health Improving[J]. CT Theory and Applications, 2001, 10(2): 41-42,18.

Catalog

    Article views (927) PDF downloads (12) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return