ISSN 1004-4140
CN 11-3017/P
XIA Zhen-ying, QI Zheng, ZHANG Ai-dong, LI Hong-jun, SONG Wen-yan. The Effect of Different Iodine Concentration of Contrast Agent in MSCT Hepatic Arterial Angiography and Its Clinical Application[J]. CT Theory and Applications, 2014, 23(2): 285-292.
Citation: XIA Zhen-ying, QI Zheng, ZHANG Ai-dong, LI Hong-jun, SONG Wen-yan. The Effect of Different Iodine Concentration of Contrast Agent in MSCT Hepatic Arterial Angiography and Its Clinical Application[J]. CT Theory and Applications, 2014, 23(2): 285-292.

The Effect of Different Iodine Concentration of Contrast Agent in MSCT Hepatic Arterial Angiography and Its Clinical Application

More Information
  • Received Date: September 10, 2013
  • Available Online: December 09, 2022
  • Objective: To evaluate the effect of different iodine concentration of contrast agent in MSCT hepatic arterial angiography and its clinical application. Method: 60 patients underwent abdominal scan. They were randomly divided into two groups and were injected with different concentration of iodine contrast agent. Group A was injected with contrast agent iohexol 300(300 mgI/mL) and group B was injected with contrast agent Ultravist 370(370 mgI/mL). The injection rate of two groups were 3.0 mL/s. We measured the level of the celiac axis, the level of the renal artery, iliac artery bifurcation at the abdominal aortic CT value and compared the CT value of the corresponding level of abdominal aortic. VR method was used in image processing. Abdominal aorta and its branches were analyzed and the image quality was evaluated. Results: The CT value of the group B was higher than that of group A(P< 0.05, the difference has statistical significance). Using VR method for hepatic artery angiography, group B has better effect in displaying the abdominal aorta and its branches(P< 0.05, the difference has statistical significance). Conclusion: At the same injection rate, the contrast agent volume of group B is less than that of group A, but the image quality of the group B is higher than that of the group A.
  • Related Articles

    [1]CHEN Zonggui, WEI Ningning, LI Zhoufan, PAN Guihong, HUANG Minjiang. Methods Research on Correction for Intracranial Metal Artifacts Based on Prior Image Utilization[J]. CT Theory and Applications, 2025, 34(1): 141-148. DOI: 10.15953/j.ctta.2024.002
    [2]LIU Bicheng, YI Xi, ZONG Chunguang, XU Yanwei, LI Liang. Ring-artifact Correction Method for Large-size Object CT Images Based on Gradient Featured Cluster Analysis[J]. CT Theory and Applications, 2024, 33(6): 781-789. DOI: 10.15953/j.ctta.2024.153
    [3]ZHANG Wenjun, HUANG Gang, DING Haining, XU Hongchun. Research Progress of Scattering Artifact Correction in Medical Cone-beam Computed Tomography Imaging Based on Deep Learning[J]. CT Theory and Applications, 2023, 32(2): 285-296. DOI: 10.15953/j.ctta.2022.131
    [4]ZUO Shunji, FENG Peng, HUANG Pan, YAN Shenghao, HE Peng, WEI Biao. Metal Artifact Reduction Algorithm for CT Images of Rock and Mineral Samples Based on Dual-domain Adaptive Network[J]. CT Theory and Applications, 2022, 31(6): 783-792. DOI: 10.15953/j.ctta.2022.041
    [5]LUO Chen, REN Qing, LIU Jianqiang, NIU Tianye. Development of Motion Artifact Correction Solutions for the Cone-beam CT Images during Pancreatic Cancer Image-guided Radiotherapy[J]. CT Theory and Applications, 2022, 31(6): 761-771. DOI: 10.15953/j.ctta.2022.066
    [6]ZHANG Xue-song, ZHAO Bo-shan. Cupping Artifacts Calibration in CT Image Based on Radon Transform[J]. CT Theory and Applications, 2016, 25(5): 539-546. DOI: 10.15953/j.1004-4140.2016.25.05.05
    [7]CHAI Jia-bin, LI Gong-ping, WEI Cun-feng, WEI Long, YU Yang, WANG Qian, LIU Bao-dong. Metal Artifacts Correction Method Research about Liquid Metal Angiography[J]. CT Theory and Applications, 2016, 25(2): 149-157. DOI: 10.15953/j.1004-4140.2016.25.02.04
    [8]LI Zhong-chuan, MENG Fan-yong, YANG Min. The Correction of Fan-beam CT Image Artifacts Induced by Deflection of Linear-detectors[J]. CT Theory and Applications, 2014, 23(2): 237-248.
    [9]WANG Xue-li. Medical CT Artifact Analysis: Reason and Correction[J]. CT Theory and Applications, 2004, 13(3): 1-8.
    [10]Zu Donglin, He Qiang, Luo Qingfei, Jin Zhen, Bao Shanglian. The Correction of Motion Artifact with fMRI Using Image Registration[J]. CT Theory and Applications, 2001, 10(4): 1-3.

Catalog

    Article views (703) PDF downloads (5) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return