ISSN 1004-4140
CN 11-3017/P
YUAN Lei-lei, ZHANG Jie, JIN Er-hu, MA Da-qing. Diagnostic Value of DCE-MRI for Breast Occupying Lesions with Calcification Detected by Mammography[J]. CT Theory and Applications, 2013, 22(3): 545-552.
Citation: YUAN Lei-lei, ZHANG Jie, JIN Er-hu, MA Da-qing. Diagnostic Value of DCE-MRI for Breast Occupying Lesions with Calcification Detected by Mammography[J]. CT Theory and Applications, 2013, 22(3): 545-552.

Diagnostic Value of DCE-MRI for Breast Occupying Lesions with Calcification Detected by Mammography

More Information
  • Received Date: February 19, 2013
  • Available Online: December 12, 2022
  • Objective:To evaluate the diagnostic value of dynamic enhanced MRI(DCE-MRI) for breast occupying lesions with calcification detected by mammography.Materials and methods Mammography and MRI data of 101 patients with breast occupying lesions containing calcification were retrospectively analyzed.Fifty six cases were malignant,including 46 cases with invasive ductal carcinoma,3 cases with ductal carcinoma in situ,2 cases with lobular carcinoma in situ,3 cases with mucous adenocarcinoma,1 case with basal cell carcinoma,1 case with myoepithelial carcinoma.Benign lesions were 45 cases,including 39 cases with breast fibroadenoma,4 cases with cyst,2 cases with fibrocystic breast hyperplasia.According to the diagnostic standard,the form of calcification was divided into three categories,including typical benign,suspicious and high suspicious malignant.The diagnosis of mammography and MRI was compared with the pathologic diagnosis,which was regarded as gold standard.The diagnostic results of mammography and MRI were statistically analyzed using McNemar's Test.Results 85 cases(84.2%) were correctly diagnosed,while 16 cases(15.8%) were misdiagnosed or diagnosed as suspicious malignant calcification by mammography.Among the 16 cases,14 of them were correctly diagnosed following DCE-MRI examination,total 99 cases were correctly diagnosed by DCE-MRI.The difference of diagnostic results based on mammography and MRI findings was significant(P = 0.0005,P< 0.05).Conclusion:When it is difficult to make a definite diagnosis for breast occupying lesions with calcification after mammography,especially for those patients with lesions in BI-RADS 3 and 4,DCE-MRI is helpful in improving diagnostic accuracy.
  • Related Articles

    [1]SU Danyang, HOU Ping, ZHANG Haoran, MA Yuanbo, LIU Jinlong, YANG Xiaopeng. Research Progress on Reducing Metal Artifacts in CT Imaging[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.023
    [2]CHEN Zonggui, WEI Ningning, LI Zhoufan, PAN Guihong, HUANG Minjiang. Methods Research on Correction for Intracranial Metal Artifacts Based on Prior Image Utilization[J]. CT Theory and Applications, 2025, 34(1): 141-148. DOI: 10.15953/j.ctta.2024.002
    [3]ZHANG Wenjun, HUANG Gang, DING Haining, XU Hongchun. Research Progress of Scattering Artifact Correction in Medical Cone-beam Computed Tomography Imaging Based on Deep Learning[J]. CT Theory and Applications, 2023, 32(2): 285-296. DOI: 10.15953/j.ctta.2022.131
    [4]LI Qiaoxin, JIN Ke, PANG Zhifeng. A Variational Model for Removing Concentric Elliptical Artifacts from CT Images[J]. CT Theory and Applications, 2022, 31(6): 773-781. DOI: 10.15953/j.ctta.2022.085
    [5]LUO Chen, REN Qing, LIU Jianqiang, NIU Tianye. Development of Motion Artifact Correction Solutions for the Cone-beam CT Images during Pancreatic Cancer Image-guided Radiotherapy[J]. CT Theory and Applications, 2022, 31(6): 761-771. DOI: 10.15953/j.ctta.2022.066
    [6]ZHANG Xue-song, ZHAO Bo-shan. Cupping Artifacts Calibration in CT Image Based on Radon Transform[J]. CT Theory and Applications, 2016, 25(5): 539-546. DOI: 10.15953/j.1004-4140.2016.25.05.05
    [7]GU Jian-wei, ZHANG Li, CHEN Zhi-qiang, XING Yu-xiang, GAO He-wei. The Review of Reasons and Correction Methods for Artifacts in ICT Images[J]. CT Theory and Applications, 2005, 14(3): 24-28.
    [8]WANG Xue-li. Medical CT Artifact Analysis: Reason and Correction[J]. CT Theory and Applications, 2004, 13(3): 1-8.
    [9]WANG Xue-li. Research and Discussion for CT Image Quality Evaluation[J]. CT Theory and Applications, 2003, 12(3): 46-52.
    [10]Zu Donglin, He Qiang, Luo Qingfei, Jin Zhen, Bao Shanglian. The Correction of Motion Artifact with fMRI Using Image Registration[J]. CT Theory and Applications, 2001, 10(4): 1-3.
  • Cited by

    Periodical cited type(2)

    1. 宋冉,梁长华,李强. 能谱CT结合血清miR-23a预测大面积急性心肌梗死患者主要心血管不良事件发生风险的价值. 海南医学. 2025(04): 528-533 .
    2. 夏宾,叶鹏飞,邵祎炜,李俊杰,李宇庆. 心肌灌注成像联合增强CT评估心肌缺血患者再灌注损伤的价值. 河南医学研究. 2024(03): 550-554 .