ISSN 1004-4140
CN 11-3017/P
XIAO Zhi-bo, ZHANG Jin-miao, CAO Xiang-yang. Technology Application Analysis Based on the Statistics of the Physical Rock Bright Spot[J]. CT Theory and Applications, 2013, 22(3): 447-454.
Citation: XIAO Zhi-bo, ZHANG Jin-miao, CAO Xiang-yang. Technology Application Analysis Based on the Statistics of the Physical Rock Bright Spot[J]. CT Theory and Applications, 2013, 22(3): 447-454.

Technology Application Analysis Based on the Statistics of the Physical Rock Bright Spot

More Information
  • Received Date: January 03, 2013
  • Available Online: December 12, 2022
  • Seismic bright spot identification method in oil and gas exploration in recent years have been widely used.According to the basic principle of physical modeling rock,through to the four of forward modeling analysis,discusses different thickness of gas sandstone and surrounding rock(mudstone) amplitude characteristic;Based on the actual well as an example,through its longitudinal wave impedance contrast,analyzes the characteristics of bright spot reasons for difference;Northern south China sea in the deep water area main oil bearing formation L sag,within conventional profile in the bright spot of that can be used as an important basis for the reservoir prediction.
  • Related Articles

    [1]YAN Xin, ZHAO Jianhua. Computed Tomography and Magnetic Resonance Imaging Diagnosis of Intracranial Solitary Fibrous Tumor: A Clinical Case Analysis[J]. CT Theory and Applications, 2024, 33(3): 365-370. DOI: 10.15953/j.ctta.2023.126
    [2]LIN Xiaoyi, JIANG Ningping. Research Progress of High-resolution Magnetic Resonance Vessel Wall Imaging in the Identification of Intracranial Arterial Stenosis Etiology[J]. CT Theory and Applications, 2024, 33(1): 97-104. DOI: 10.15953/j.ctta.2022.215
    [3]WANG Shan, ZHAO Jianhua. Research Progress in Imaging Radiomics Based on Computed Tomography and Magnetic Resonance in Ischemic Stroke[J]. CT Theory and Applications, 2024, 33(1): 83-89. DOI: 10.15953/j.ctta.2023.080
    [4]HE Weihong, FU Xi, FANG Tingsong, WANG Guining, WANG Juan. Application Value of Segond Fracture Imaging Features in Lateral Knee Instability[J]. CT Theory and Applications, 2023, 32(6): 771-776. DOI: 10.15953/j.ctta.2022.112
    [5]ZHU Lan, PAN Zi-lai. The Utilization of Diffusion-weighted Magnetic Resonance Imaging in the Detection of Lymph-node Metastasis in Rectal Cancer[J]. CT Theory and Applications, 2014, 23(3): 527-533.
    [6]LI Jing-ying, WANG Xiu-ling, WU Meng. Imaging Features of Solid Pseudopapillary Tumor of the Pancreas on Computed Tomography and Magnetic Resonance Imaging[J]. CT Theory and Applications, 2013, 22(1): 161-166.
    [7]JIANG Li-hua, CHEN Xiao-bo, YUE Yun-long, ZHAO Li-jun, DUAN Yong-li, FU Yan. Magnetic Resonance Imanging Diagnosis of Limbs Lymphangioma[J]. CT Theory and Applications, 2012, 21(2): 313-319.
    [8]YANG Hai-peng, JIN Er-hu, ZHANG Jie, CHEN Bu-dong, MA Da-qing. Diagnosis of Gallbladder Enlargement on Magnetic Resonance Cholangiopancreatography Combined with Conventional MR Images[J]. CT Theory and Applications, 2011, 20(3): 403-414.
    [9]WANG Wei-dong, BAO Shang-lian. Decomposition of Magnetic Resonance Images by Estimating MR Physical Parameters[J]. CT Theory and Applications, 2006, 15(4): 73-78.
    [10]Yu Bingbing, Li Guoying, Li Jie. Application of STIR Sequence in The Lesion of Knee[J]. CT Theory and Applications, 2000, 9(2): 22-23.

Catalog

    Article views (773) PDF downloads (5) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return