ISSN 1004-4140
CN 11-3017/P
HUO Mei-chun, LI Hao, ZHANG Yan-ming, WU Jian-yi, MO Yang, CAO Qin-qin. The Implementation of a Conveying System Based on Synchronous Belt Drive in CT Security Equipment[J]. CT Theory and Applications, 2012, 21(3): 443-448.
Citation: HUO Mei-chun, LI Hao, ZHANG Yan-ming, WU Jian-yi, MO Yang, CAO Qin-qin. The Implementation of a Conveying System Based on Synchronous Belt Drive in CT Security Equipment[J]. CT Theory and Applications, 2012, 21(3): 443-448.

The Implementation of a Conveying System Based on Synchronous Belt Drive in CT Security Equipment

More Information
  • Received Date: May 17, 2012
  • Available Online: December 12, 2022
  • Computed tomography security inspection equipment for luggage and package is aimed at spiral scan and spot scan test for luggage and package.The conveying system is an important part of the equipment.The operation stability and accuracy of the conveying system will affect the quality of scanning image and image acquisition of contraband.The need to research and develop a specific conveying system for computed tomography security equipment and several technical difficulties to be solved are described.A new type of conveying system with a built-in servo motor,a synchronous belt to drive,a controlled feed speed,a high positioning accuracy and the modular design method,which is designed to solve the difficulties mentioned above,is discussed briefly.The conveying system supports the integral design of the CT security inspection instrument well and ensures the smooth realization of the entire system function.
  • Related Articles

    [1]CAO Jiasheng, LI Baolei. Analysis of Accuracy Related Factors in Photon Counting X-ray CT Energy Imaging[J]. CT Theory and Applications, 2025, 34(2): 255-262. DOI: 10.15953/j.ctta.2024.254
    [2]WANG Ce, ZHOU Fengyun, XUAN Yanjiao, WANG Wenhai, YAO Lin, SHI Zheng, MA Yongzhong, CHENG Xiaoguang. Measurement and Analysis of Gonadal Irradiation Dose During Singe-shot X-ray Exposure of Both Lower Limbs[J]. CT Theory and Applications, 2024, 33(5): 627-632. DOI: 10.15953/j.ctta.2023.171
    [3]SUN Guangjiang, YAO Xiaosheng, YANG Dongxiang. Analysis of the Value of Three-dimensional CT and X-ray Examination in Calcaneal Fractures[J]. CT Theory and Applications, 2019, 28(3): 371-376. DOI: 10.15953/j.1004-4140.2019.28.03.11
    [4]FENG Xia, SHI Chao, DING Wen-bo, FENG Yan, HAO Zhen-ping. The Complication of Spectral Analysis Based on Fourier Transform in the Tire X-ray Detection[J]. CT Theory and Applications, 2014, 23(3): 453-458.
    [5]HUO Mei-chun, DONG Guo-ping, LIANG Ze, LI Hao, LIU Dan, GU Dong-bo, MIAO Xiang-yue. Development and Application Analysis of a Tester for X-ray Detectors[J]. CT Theory and Applications, 2012, 21(4): 699-704.
    [6]ZHANG Jun-sheng, WANG Ming-quan, GUO Yong-liang, CHEN Zhi-qiang. Analysis of X-ray Digital Imaging System Resolution[J]. CT Theory and Applications, 2011, 20(2): 227-234.
    [7]HOU Ying, SUN Yi. Analysis on Application of Calibration Method for Cone-beam X-CT[J]. CT Theory and Applications, 2011, 20(2): 211-220.
    [8]ZHU Hua-qiang, LIU Si-run, QIU Jian, LUO Dong-mei, ZHOU De-ming. X-ray and CT Image Analysis of Pelvic Fractures[J]. CT Theory and Applications, 2011, 20(1): 83-90.
    [9]SONG Fu-jing, TONG Jing, JI Zhi-min, ZHANG Bo, JIANG Guo-lin, ZHANG Guang-ping. To Analysis The Chest X-ray Character of SARS[J]. CT Theory and Applications, 2004, 13(2): 33-36.
    [10]WANG Xue-li. Spatial Resolution and Fourier Analysis for X-ray Medical Device[J]. CT Theory and Applications, 2003, 12(4): 36-41.

Catalog

    Article views (906) PDF downloads (6) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return