ISSN 1004-4140
CN 11-3017/P
ZHUANG Gao-ming, YE Hai-ming, LIN Bo-miao, YE Qiang. The Value of 64-slice Spiral CT Angiography in Diagnosing Aortic Dissection[J]. CT Theory and Applications, 2012, 21(2): 291-296.
Citation: ZHUANG Gao-ming, YE Hai-ming, LIN Bo-miao, YE Qiang. The Value of 64-slice Spiral CT Angiography in Diagnosing Aortic Dissection[J]. CT Theory and Applications, 2012, 21(2): 291-296.

The Value of 64-slice Spiral CT Angiography in Diagnosing Aortic Dissection

More Information
  • Received Date: January 03, 2012
  • Available Online: December 09, 2022
  • Objective:To investigate the value of 64-slice spiral CT angiography in diagnosing aortic dissection. Methods:Retrospective analysis 10 cases of aortic dissection in 2009 to 2011 first half,all diagnose by 64-slice spiral CT angiography,and 6 cases Treatment by DSA.Results:CT results,6 cases were classified with Stanford type B,and 4 cases with Stanford type A.Six cases of Stanford B type treated by aortic endovascular repair of stent-graft.Postoperative classification are full compliance with CT.Four cases of Stanford type A are considered by Clinical unsuitable for Interventional procedures,conservative treatment,no surgical.Conclusion:The 64-slice spiral CT angiography not only a good diagnosis method of aortic dissection,but also can type correctly,guide treatment.
  • Related Articles

    [1]WANG Lin, QU Gangrong. The Numerical Solution of the Radon Transform Along the Circular Curve[J]. CT Theory and Applications, 2020, 29(3): 329-336. DOI: 10.15953/j.1004-4140.2020.29.03.09
    [2]HE Tian, SHAN Tianshu, KONG Dehui, WANG Yakun, WANG Chengyong, WU Faen, CHEN Licheng. Algebraic Reconstruction Method Physical Model Ultrasonic Image Reconstruction[J]. CT Theory and Applications, 2019, 28(3): 311-321. DOI: 10.15953/j.1004-4140.2019.28.03.04
    [3]CHEN Xuananga, ZHANG Shia, LI Zhiyonga, WU Dib, WANG Chengyonga, WU Faena, CHEN Lichenga. Algebraic Reconstruction and Structure Recognition for Ultrasound CT Image on Physical Model[J]. CT Theory and Applications, 2019, 28(2): 195-204. DOI: 10.15953/j.1004-4140.2019.28.02.05
    [4]GONG Shu, REN Qin-qin, WANG Min-ling. Application of Parabolic Radon Transform in the Suppression of Multiple Seismic Wave[J]. CT Theory and Applications, 2017, 26(2): 165-176. DOI: 10.15953/j.1004-4140.2017.26.02.05
    [5]ZHANG Xue-song, ZHAO Bo-shan. Cupping Artifacts Calibration in CT Image Based on Radon Transform[J]. CT Theory and Applications, 2016, 25(5): 539-546. DOI: 10.15953/j.1004-4140.2016.25.05.05
    [6]CHEN Xiong, WANG Cheng-yong, WU Di, WU Fa-en, CHEN Li-cheng. Reconstruct Digital Image by Algebraic Reconstruction Technique Based Programming[J]. CT Theory and Applications, 2015, 24(4): 485-493. DOI: 10.15953/j.1004-4140.2015.24.04.02
    [7]WANG Li-xin, HUANG Guang-tan, ZHANG Bin-bin, ZHU Wen-bo, ZHANG Jun-hua. Suppressing Method Study and Application of Seismic Scattered Wave Based on Local Hyperbolic Radon Transform[J]. CT Theory and Applications, 2014, 23(1): 27-36.
    [8]XU Hai-jun, WEI Dong-bo, FU Jian, ZHANG Li-kai, DAI Xiu-bin. Fast Computation of 3D Radon Transform Via a Geometrical Method[J]. CT Theory and Applications, 2008, 17(2): 1-7.
    [9]Zhang Tie, Yan Jiabin. The Error Analysis of Improved Fourier Algorithm for Solving Radon Transform[J]. CT Theory and Applications, 2000, 9(1): 12-16.
    [10]Wang Jinping. The Inversion Formula of Radon Transform in R2[J]. CT Theory and Applications, 2000, 9(1): 8-11.

Catalog

    Article views (763) PDF downloads (1) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return