ISSN 1004-4140
CN 11-3017/P
JI Shu-wen, CHAO Hui-min, GAO Bin, CHEN Wang. The Research and Solution Scheme on Relationship between Dual-Source CT Coronary Artery CTA Artifact and Heart Rate Change[J]. CT Theory and Applications, 2011, 20(3): 377-382.
Citation: JI Shu-wen, CHAO Hui-min, GAO Bin, CHEN Wang. The Research and Solution Scheme on Relationship between Dual-Source CT Coronary Artery CTA Artifact and Heart Rate Change[J]. CT Theory and Applications, 2011, 20(3): 377-382.

The Research and Solution Scheme on Relationship between Dual-Source CT Coronary Artery CTA Artifact and Heart Rate Change

More Information
  • Received Date: May 06, 2011
  • Available Online: December 14, 2022
  • Purpose: The reason of imaging quality and wrong layer artifact of coronary arteries CTA with Dual-source CT and heart rate and to discuss the reason of poor imaging quality and the solution.Method: 70 cases of coronary arteries CTA imaging and ECG data of patients with suspected coronary artery disease from February 2010 to July 2010 were retrospectively analyzed.The difference of average heart rate,fluctuation of heart rate,variation of heart rate and average R-R period between the patients who has artifact and no artifact was compared.Results: Average heart rate,fluctuation of heart rate,variation of heart rate and average R-R period between the patients who has artifact and no artifact is no significant difference.Conclusion: Use in the double source CT in,average heart rate,heart rate motion,heart rate variation and average R-R expect to etc.parameter to isn't direct or mainly cause picture quality poor and wrong layer false shadow of main reason,this and double equipments function and data of the source CT collect a way relevant.Because the reason of picture false shadow is a heart Lyu not and together,the body in the scanning process move and appear false movie queen to carry on a heart electricity editor afresh detection and choose sport that is different to move period heart mutually same reconstruction time the window can rectify a wrong layer false shadow.
  • Related Articles

    [1]HUANG Yunfei, LI Xuan, CHEN Ping. A Three-dimensional BGA Solder Ball Defect Detection Method Based on YOLOv8 and Metric Analysis[J]. CT Theory and Applications, 2025, 34(2): 235-243. DOI: 10.15953/j.ctta.2024.237
    [2]HE Weihong, FANG Tingsong, FU Xi, LAO Meiling, XIAO Xiuyun. Risk Factors of Vulnerable Coronary Plaque Formation in Type 2 Diabetes[J]. CT Theory and Applications, 2023, 32(4): 523-529. DOI: 10.15953/j.ctta.2023.036
    [3]SUN Pengtao, DOU Xuechao, YAN Yuchang, LIAN Yufei, LIU Chenpeng, PAN Zhenyu. Application of T2WI 3D-SPACE Imaging in Preoperative Evaluation of Rectal Cancer[J]. CT Theory and Applications, 2021, 30(3): 340-346. DOI: 10.15953/j.1004-4140.2021.30.03.07
    [4]LV Xuefei, HU Shaoping. A Preliminary Study on the Correlation between MRI Diffusion Characteristics and HER-2 Expression in Female Breast Cancer[J]. CT Theory and Applications, 2020, 29(5): 584-590. DOI: 10.15953/j.1004-4140.2020.29.05.09
    [5]FANG Fang, TAN Wei, HU Shaoping. Feasibility Analysis of MCTSI Combined with D-dimmer in Evaluating the Clinical Prognosis of Patients with Acute Pancreatitis[J]. CT Theory and Applications, 2019, 28(1): 139-146. DOI: 10.15953/j.1004-4140.2019.28.01.15
    [6]TAN Jing-wen, PAN Zi-lai, ZHANG Huan, SHI Bo-wen, ZHU Lan, GAO Xiao-yuan. The Value of 2D MRI and 3D MRI Sequences in Preoperative Staging of Rectal Cancer[J]. CT Theory and Applications, 2017, 26(4): 457-465. DOI: 10.15953/j.1004-4140.2017.26.04.07
    [7]GAO Xiang, YUAN Yan-wen, JIN Er-hu, ZHANG Jie, HONG Xu, YANG Zheng-han, MA Da-qing. Study of Liver Fat Content in Patients with Newlydiagnosed Type 2 Diabetes Mellitus on Chemical Shift MRI[J]. CT Theory and Applications, 2016, 25(4): 385-392. DOI: 10.15953/j.1004-4140.2016.25.04.01
    [8]ZHANG Er-hua, MA Ren-an, ZHAO Chun-xia, YANG Jing-yu. Visualization of 3-D Seismic Data in Virtual Reality[J]. CT Theory and Applications, 2003, 12(1): 6-12.
    [9]HUANG Yong-ping, XIA Dai-xue. The Application of 3-D High Resolution Seismic Exploration Technology in Well 2 of Mobei in Zhungaer Basin[J]. CT Theory and Applications, 2002, 11(2): 5-8.
    [10]QIANG Jian-ke, XIONG Bin, RUAN Bai-yao. The Character Analysis of True and False Approximate Resistivity Anomaly in Numerical Modeling of 3-D Geo-electrical Model[J]. CT Theory and Applications, 2002, 11(1): 6-9.

Catalog

    Article views (713) PDF downloads (6) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return