ISSN 1004-4140
CN 11-3017/P
LÜ Xin-rong. An Interactive Approach for Skull Defect Repair Based on CT Sequence Datasets[J]. CT Theory and Applications, 2011, 20(1): 73-82.
Citation: LÜ Xin-rong. An Interactive Approach for Skull Defect Repair Based on CT Sequence Datasets[J]. CT Theory and Applications, 2011, 20(1): 73-82.

An Interactive Approach for Skull Defect Repair Based on CT Sequence Datasets

Funds: 

Fund of China University of Petroleum(East China)(No.Y0905011)

More Information
  • Received Date: October 11, 2010
  • Available Online: December 12, 2022
  • Skull bone is one of the most important parts in the human's body,which protects and supports the brain tissues. Nowadays,due to many various reasons,a lot of people suffer from the skull bone defects,which not only affect the appearance,but also may cause brain damages. How to repair the skull bones for people effectively has become an international hot topic. At present,doctors diagnose the state of the bone defect illness mainly depending on observing the CT images of patients,and make the repair model by hand. It mainly depends on the technique and experience of the doctors. In order to solve this problem,this paper focuses on using the interactive technology to make the skull repair procedure efficient. During this process,we used B-Spline to repair some typical slices or each slice of the CT images,construct the restoration that fits the skull surface and then transfer it as a file in specific format to a machine based on technology of computer aided design and computer aided manufacture to produce a real restoration. This method can shorten the time of operation,reduce the risk of operation,and produce a suitable repair result for patients.
  • Related Articles

    [1]JI Wenchao, TIAN Weili, LIU Wenya, HE Lianghao, YANG Jian. Application of the Canon 320 Row Variable Helical Pitch CTA System Combined with Iterative Reconstruction Technology for Lower Limb Vascular Imaging[J]. CT Theory and Applications, 2025, 34(1): 149-154. DOI: 10.15953/j.ctta.2024.009
    [2]XIE Ruigang, WANG Siyan, AN Hengbin, SU Tao, SUN Minghua. Impact of Electrocardiogram Gating Technology on Radiation Dose in Dual-source Computed Tomography High Pitch Spiral Scanning Using a Phantom[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.300
    [3]WANG Chensi, HONG Yao, FANG Huimin, DING Xuelu, YANG Yifan, TIAN Xiangbao, CHEN Wenjing, WANG Yongsheng. Based on the Effect of Different Pitches on Neck CTA Radiation Dose and Image Quality under Automatic Tube Current Modulation Technology[J]. CT Theory and Applications, 2024, 33(3): 309-315. DOI: 10.15953/j.ctta.2023.148
    [4]LIU Dandan, LI Wei, ZHANG Yongxian, ZHAO Bo, CUI Ying, KANG Tianliang, MA Zixuan, LIU Yuhang, NIU Yantao. Preliminary exploration of non-gated high-pitch chest CT combined with artificial intelligence in assessing coronary artery calcium score[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.085
    [5]YANG Zhengjun, ZHANG Ang, CHEN Yong, JIANG Jiang, WANG Lingyun, ZHANG Yong, ZHANG Xuan, QI Xiaofeng. The Effect of Radiation Dose and Tube Potential on Image Quality of CT: A Task-based Image Quality Assessment[J]. CT Theory and Applications, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060
    [6]WU Tenghui, ZHA Yunfei, YANG Feng. The Study of Application of Different Pitch Combined with ASIR in Low-dose Chest CT Screening on COVID-19[J]. CT Theory and Applications, 2022, 31(2): 186-194. DOI: 10.15953/j.1004-4140.2022.31.02.05
    [7]GUO Wei-ya, LIU Yi-jun, LIU Ai-lian. To Explore the Influence of GSI Data of Standard Model in Different Pitch of Single Source-dual Energy CT[J]. CT Theory and Applications, 2017, 26(3): 279-284. DOI: 10.15953/j.1004-4140.2017.26.03.03
    [8]BAO Li-wei, WANG Ze-feng, SUN Zhen-ting, MENG Ling-xin, ZHAO Lei. Evaluation of Image Quality and Radiation Dose for Low-tube Voltage Head and Neck CTA[J]. CT Theory and Applications, 2015, 24(1): 87-94. DOI: 10.15953/j.1004-4140.2015.24.01.10
    [9]FU Chuan-ming, WU De-hong, XU Lin, CHEN Lun-gang, WANG Zhong-ping, XIONG Yin. Reduce the Radiation Dose in the Lower Extremities to Explore the Feasibility of CTA[J]. CT Theory and Applications, 2014, 23(3): 467-473.
    [10]ZHOU Ze-jun, HU Yong-sheng, GAO Bin, CHAO Hui-ming. Expounding the Pitch,Thickness,Reconstructing Space of Multislice CT and Influencing the Imaging Quality[J]. CT Theory and Applications, 2008, 17(1): 21-26.

Catalog

    Article views (1638) PDF downloads (3) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return