ISSN 1004-4140
CN 11-3017/P
WU Kun, PAN Jin-xiao. The Projection Ordering Scheme of Three-dimensional Cone-beam for ART[J]. CT Theory and Applications, 2010, 19(4): 61-70.
Citation: WU Kun, PAN Jin-xiao. The Projection Ordering Scheme of Three-dimensional Cone-beam for ART[J]. CT Theory and Applications, 2010, 19(4): 61-70.

The Projection Ordering Scheme of Three-dimensional Cone-beam for ART

More Information
  • Received Date: July 05, 2010
  • Available Online: December 12, 2022
  • The order of the applied projections in Algebraic Reconstruction Technique(ART) has a great effect on speed of convergence and accuracy in reconstructed image.In 3D cone-beam ART,some schemes of the sort of the projection sequence are compared in the paper.The schemes are listed below:Sequence Access(SAS),Multilevel(MLS),Prime Number Decomposition(PND),and Weighted Distance(WDS).The experiment results got by simulation experiment show that the speed of convergence on which reconstructed image by MLS,PND and WDS is more quick than by SAS,and the WDS is the best one in three sort schemes.
  • Related Articles

    [1]XIANG Ronglin, ZHANG Li. Suppression Method for Cone-Beam CT Artifact Based on FDK Compensation and Dual-Source Weighting[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.222
    [2]XU Tongjiang, WANG Xu, LI Yan, DENG Gang, LIU Jianxin, YIN Xiaoming, LIANG Weizhong, WU Ge. Application of IMR, iDose<sup<4</sup< and FBP Reconstruction Algorithms in CT Scanning of Rhinoplasty[J]. CT Theory and Applications, 2022, 31(3): 357-364. DOI: 10.15953/j.ctta.2021.072
    [3]LV Zhentao, GUI Zhiguo, LIU Yi, ZHANG Pengcheng. Industrial CT Rotation Center Calibration Method Based on Weighted Average[J]. CT Theory and Applications, 2021, 30(5): 539-546. DOI: 10.15953/j.1004-4140.2021.30.05.01
    [4]WANG Jing-yu, HAN Yu, LI Lei, XI Xiao-qi, SUN Yan-min, YAN Bin. A Novel Reconstruction Algorithm Based-on Projection Transformation for the Rotational Cone-beam CL[J]. CT Theory and Applications, 2017, 26(5): 575-582. DOI: 10.15953/j.1004-4140.2017.26.05.06
    [5]YUAN Ye, HUANG Xiao-han, WANG Zhong-gang, ZHANG Yu, JIANG Zheng. The Method of Inversion Imaging Based on Matrix Pretreatment and BPT-SIRT Nonlinear Weighted[J]. CT Theory and Applications, 2017, 26(1): 53-62. DOI: 10.15953/j.1004-4140.2017.26.01.07
    [6]HU Jun-jie, MA Chen-xin, YAN Bin. Optimization of Filter Function in CT Image Reconstruction[J]. CT Theory and Applications, 2013, 22(1): 85-92.
    [7]LIU Liang, ZHANG Bin, PAN Jin-xiao. An Improved FBP Arithmetic Based on Detector’s Width[J]. CT Theory and Applications, 2007, 16(1): 54-59.
    [8]YUAN Ming-kai, LIU Li. Comparative Analysis of FBP and OSEM Reconstruction Methods in Industrial CT[J]. CT Theory and Applications, 2006, 15(1): 56-60.
    [9]CHEN Zhi-qiang, LI Liang, KANG Ke-jun, ZHANG Li. New Developments of exact Cone-beam CT Reconstruction Algorithms[J]. CT Theory and Applications, 2005, 14(3): 65-70.
    [10]LIU Li, WU Xiao-feng, YIN Yin. Positron Emission Tomography and PET Image Reconstruction[J]. CT Theory and Applications, 2003, 12(1): 47-50.

Catalog

    Article views PDF downloads Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return