ISSN 1004-4140
CN 11-3017/P
LIANG Wen-xuan, HU Guang-shu. On the 2D Fan-beam CT Reconstruction from Insufficient Projection Data[J]. CT Theory and Applications, 2010, 19(3): 1-12.
Citation: LIANG Wen-xuan, HU Guang-shu. On the 2D Fan-beam CT Reconstruction from Insufficient Projection Data[J]. CT Theory and Applications, 2010, 19(3): 1-12.

On the 2D Fan-beam CT Reconstruction from Insufficient Projection Data

Funds: 

National Basic Research Program of China (973) under Grant No.2006CB705700

Texas Instruments Innovation Funds

More Information
  • Received Date: May 30, 2009
  • Available Online: December 12, 2022
  • CT reconstruction from insufficient data is important in many medical and other applications.Recently to solve this under-determined problem,the Total Variation minimization method has regained popularity due to the newly-emerging compressed sensing theory.In this paper TV-minimization is extended to a more general framework for CT reconstuction from insufficient data.The framework proposed is also based on the compressed sensing theory,but is more flexible and amenable to various applications.Analysis and simulations are conducted for an initial special case and promising results are achieved.
  • Related Articles

    [1]LI Yangsen, QIN Dewen, LIU Qingwen, WANG Xiaopei, Liu Xiaohui. Research on the Identification of Sandstone Vanishing Points Based on Synchronous Compression Matching Pursuit Method[J]. CT Theory and Applications, 2024, 33(5): 551-560. DOI: 10.15953/j.ctta.2024.001
    [2]CHEN Yun-bin, WANG Yuan, LIU Qing-hua. Several Methods for Reducing the Dose of Cone Beam CT[J]. CT Theory and Applications, 2017, 26(3): 327-334. DOI: 10.15953/j.1004-4140.2017.26.03.09
    [3]XIAO Kai-pan, ZHANG Da, ZHANG Fan-chang. The Bayes Sparse Spike Inversion Based on Spatial Variable Impedance Coefficient[J]. CT Theory and Applications, 2015, 24(6): 809-817. DOI: 10.15953/j.1004-4140.2015.24.06.06
    [4]HE Tai-ming, LIU Zheng-yi, LI Shi-yu. Experimental Studies of Ultrasonic Tomography on Fangshan Granite under Uniaxial Compression[J]. CT Theory and Applications, 2015, 24(5): 657-665. DOI: 10.15953/j.1004-4140.2015.24.05.03
    [5]ZHOU Chun-yan, LI Bo, DING Hou-ben. The Study of A Newly-mode Embedded Multi-channel Pulse Amplitude Analyzer[J]. CT Theory and Applications, 2015, 24(1): 69-77. DOI: 10.15953/j.1004-4140.2015.24.01.08
    [6]LI Shou-tao, CHEN Hao, CHEN Si, LI Jing. Image ROI Selection and its Application[J]. CT Theory and Applications, 2014, 23(6): 979-984.
    [7]LIU Yu-ping, LI Li-qing, XUE Hua, DENG Gui-lin, ZHANG Bao-jin. Frequency Shift Processing for the Hypocenter with Short-term Single-frequency Pulse in the Ocean Sub-bottom Profile Data[J]. CT Theory and Applications, 2014, 23(2): 227-235.
    [8]LI Zhang-zheng, SHI Fang-fang, WU He-zhen. Research on Inspecting Concrete Flaws with LFM Signal[J]. CT Theory and Applications, 2014, 23(1): 19-26.
    [9]JIAO Peng-fei, LI Liang, ZHAO Ji. New Advances of Compressed Sensing in Medical Image Reconstruction[J]. CT Theory and Applications, 2012, 21(1): 133-147.
    [10]WU He-zhen, HE Tai-ming. Simulation Study on Coded Excitation in Rock Property Ultrasound Imaging[J]. CT Theory and Applications, 2010, 19(4): 45-52.

Catalog

    Article views (1529) PDF downloads (7) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return