ISSN 1004-4140
CN 11-3017/P
WANG Xin-e, TAN Mao-jin. Environment Correction and Application of Porosity Logging Data in Carbonate Formations[J]. CT Theory and Applications, 2010, 19(2): 43-52.
Citation: WANG Xin-e, TAN Mao-jin. Environment Correction and Application of Porosity Logging Data in Carbonate Formations[J]. CT Theory and Applications, 2010, 19(2): 43-52.

Environment Correction and Application of Porosity Logging Data in Carbonate Formations

More Information
  • Received Date: March 21, 2010
  • Available Online: December 12, 2022
  • Seismic reservoir prediction requires high-precision logging data, namely Environment correction of logging data is necessary in reservoirs as well as non-reservoirs. To Eliminate the impacts of borehole collapse and other factors on logs, put forward the first to find out the abnormal of log curve, according to the abnormal, a set of correction methods for the sonic logging data and density logging data are proposed of respectively, such as reprocessing of array acoustic logging data and reconstruct-editing method. These methods were be used in carbonate rocks in the northeastern of Sichuan province. The results prove show these methods effective and correct. The ideas and methods are promising for other formations and areas.
  • Related Articles

    [1]CHEN Zhao, WANG Rongfu. Application of CT in the Diagnosis and Differential Diagnosis of Novel Coronavirus Pneumonia[J]. CT Theory and Applications, 2020, 29(3): 273-279. DOI: 10.15953/j.1004-4140.2020.29.03.02
    [2]MIAO Na, QI Xuhong, DU Changyue, CHEN Shiguang, BI Dongmei, WEN Zhiyong. The Application Value of Chest Multi-slice Spiral CT in the Diagnosis of Mass in Dense Breast[J]. CT Theory and Applications, 2020, 29(1): 79-88. DOI: 10.15953/j.1004-4140.2020.29.01.10
    [3]LI Yanju, LIU Xiaoxing, LIANG Shanshan, RAN Caihong, NNDA Zhuoma. Guidance Value of MSCT in the Diagnosis and Clinical Treatment of GST[J]. CT Theory and Applications, 2020, 29(1): 71-77. DOI: 10.15953/j.1004-4140.2020.29.01.09
    [4]ZHU Lu, HAO Fene. Diagnosis and Analysis of Laryngeal Chondrosarcoma with MSCT[J]. CT Theory and Applications, 2019, 28(5): 625-630. DOI: 10.15953/j.1004-4140.2019.28.05.13
    [5]SHEN Chun-lin, WAN Zhe-jun, LIU Yue-jun, XU Xiao-hu. Analysis of MSCT Diagnosis and Misdiagnosis of Early Central Type Lung Cancer[J]. CT Theory and Applications, 2017, 26(2): 253-258. DOI: 10.15953/j.1004-4140.2017.26.02.15
    [6]WANG Ye-qing, JIA Zheng-wei, LI Hao, LI Xiao-feng. Application of MSCT-VHSG in the Diagnosis of Fallopian Tube Patency[J]. CT Theory and Applications, 2015, 24(5): 733-738. DOI: 10.15953/j.1004-4140.2015.24.05.11
    [7]ZHANG Hai-bo, HU Xi-yao, FU Chuan-ming, XU Lin, WANG Kai-hua. MSCT One-stop Recombination in Lumbar Disease Diagnosis Application Value[J]. CT Theory and Applications, 2012, 21(1): 81-88.
    [8]XU Guan-zhen, FU Chuan-ming, JIANG Lin. CT Diagnosis of the External Hydrocephalus[J]. CT Theory and Applications, 2011, 20(3): 397-401.
    [9]ZHAO Lin, CHEN You-san, SUN Zhi-qiang, YANG Yu-heng, SONG Jia, SHEN Gui-ping, LIU Xin, TIAN Long-hai, CHEN Xin-jian. MSCT Diagnosis of Pedunculated Hepatocellular Carcinoma[J]. CT Theory and Applications, 2010, 19(4): 79-84.
    [10]FU Chuan-ming, CHEN Yi-jia, CHEN Xue-qiang, CHEN Lun-gang, ZOU Jian-hua, WU Wen-qiang. MSCT and X-ray: The Comparison of Clinical Value in the Diagnosis of Lumbar Spondylolisthesis[J]. CT Theory and Applications, 2010, 19(3): 67-73.

Catalog

    Article views PDF downloads Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return