ISSN 1004-4140
CN 11-3017/P
MING Jian-zhong, ZENG Zhi-bin, ZHONG Wen-xin, PENG Ke-wen, SHEN Bi-xian. The Application of Bone Subtraction 3D-CTA for the Evaluation of Cerebral Vascular Disease[J]. CT Theory and Applications, 2010, 19(1): 82-86.
Citation: MING Jian-zhong, ZENG Zhi-bin, ZHONG Wen-xin, PENG Ke-wen, SHEN Bi-xian. The Application of Bone Subtraction 3D-CTA for the Evaluation of Cerebral Vascular Disease[J]. CT Theory and Applications, 2010, 19(1): 82-86.

The Application of Bone Subtraction 3D-CTA for the Evaluation of Cerebral Vascular Disease

More Information
  • Received Date: October 19, 2009
  • Available Online: December 12, 2022
  • Objective:To explore the diagnosis evaluation of DSCT with boneless subtraction 3D-CTA in cerebral on;3D-CTA;cerebral vascular disease vascular disease.Methods:DSCT with boneless subtraction 3D-CTA of 60 patients with suspected clinically cerebral vascular diseases were analyzed retrospectively all axial images were transferred to an external workstation.The reconstructed images were processed into volume rendering (VR),multiplanar reconstruction (MPR) and maximum intensity projection (MIP),the values were valuably compared with the results of surgery or DSA.Results:9 cases were aneurysms,29 cases were cerebral artery stenos is or occlusion,3 cases were AVM,19 cases were normal.Conclusion:DSCT with boneless subtraction 3D-CTA is a valuable diagnostic method for various cerebral vascular diseases.
  • Related Articles

    [1]HUANG Yunfei, LI Xuan, CHEN Ping. A Three-dimensional BGA Solder Ball Defect Detection Method Based on YOLOv8 and Metric Analysis[J]. CT Theory and Applications, 2025, 34(2): 235-243. DOI: 10.15953/j.ctta.2024.237
    [2]HE Weihong, FANG Tingsong, FU Xi, LAO Meiling, XIAO Xiuyun. Risk Factors of Vulnerable Coronary Plaque Formation in Type 2 Diabetes[J]. CT Theory and Applications, 2023, 32(4): 523-529. DOI: 10.15953/j.ctta.2023.036
    [3]SUN Pengtao, DOU Xuechao, YAN Yuchang, LIAN Yufei, LIU Chenpeng, PAN Zhenyu. Application of T2WI 3D-SPACE Imaging in Preoperative Evaluation of Rectal Cancer[J]. CT Theory and Applications, 2021, 30(3): 340-346. DOI: 10.15953/j.1004-4140.2021.30.03.07
    [4]LV Xuefei, HU Shaoping. A Preliminary Study on the Correlation between MRI Diffusion Characteristics and HER-2 Expression in Female Breast Cancer[J]. CT Theory and Applications, 2020, 29(5): 584-590. DOI: 10.15953/j.1004-4140.2020.29.05.09
    [5]FANG Fang, TAN Wei, HU Shaoping. Feasibility Analysis of MCTSI Combined with D-dimmer in Evaluating the Clinical Prognosis of Patients with Acute Pancreatitis[J]. CT Theory and Applications, 2019, 28(1): 139-146. DOI: 10.15953/j.1004-4140.2019.28.01.15
    [6]TAN Jing-wen, PAN Zi-lai, ZHANG Huan, SHI Bo-wen, ZHU Lan, GAO Xiao-yuan. The Value of 2D MRI and 3D MRI Sequences in Preoperative Staging of Rectal Cancer[J]. CT Theory and Applications, 2017, 26(4): 457-465. DOI: 10.15953/j.1004-4140.2017.26.04.07
    [7]GAO Xiang, YUAN Yan-wen, JIN Er-hu, ZHANG Jie, HONG Xu, YANG Zheng-han, MA Da-qing. Study of Liver Fat Content in Patients with Newlydiagnosed Type 2 Diabetes Mellitus on Chemical Shift MRI[J]. CT Theory and Applications, 2016, 25(4): 385-392. DOI: 10.15953/j.1004-4140.2016.25.04.01
    [8]ZHANG Er-hua, MA Ren-an, ZHAO Chun-xia, YANG Jing-yu. Visualization of 3-D Seismic Data in Virtual Reality[J]. CT Theory and Applications, 2003, 12(1): 6-12.
    [9]HUANG Yong-ping, XIA Dai-xue. The Application of 3-D High Resolution Seismic Exploration Technology in Well 2 of Mobei in Zhungaer Basin[J]. CT Theory and Applications, 2002, 11(2): 5-8.
    [10]QIANG Jian-ke, XIONG Bin, RUAN Bai-yao. The Character Analysis of True and False Approximate Resistivity Anomaly in Numerical Modeling of 3-D Geo-electrical Model[J]. CT Theory and Applications, 2002, 11(1): 6-9.

Catalog

    Article views (1561) PDF downloads (3) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return