ISSN 1004-4140
CN 11-3017/P
FAN Xu, GUO Zhi-rui, CAO Min, ZHOU Xue-feng, GU Ning. Contrast Agents for Computed Tomography Based on Gold Nanoparticles[J]. CT Theory and Applications, 2009, 18(4): 15-25.
Citation: FAN Xu, GUO Zhi-rui, CAO Min, ZHOU Xue-feng, GU Ning. Contrast Agents for Computed Tomography Based on Gold Nanoparticles[J]. CT Theory and Applications, 2009, 18(4): 15-25.

Contrast Agents for Computed Tomography Based on Gold Nanoparticles

More Information
  • Received Date: July 02, 2009
  • Available Online: December 14, 2022
  • Gold nanoparticles hold excellent surface properties,multiple synthestic routes and good biocompatibility.Currently,the commercial clinical Computed Tomography(CT)contrast agents are iodine based organic molecules.Compared with iodine,Gold has a larger atomic number and X-ray absorption coefficient.In recent years,quite a few works about using gold nanoparticles as CT contrast agents have been published.In this review,We outlined the synthesis routes,surface modification,and the behaviors of gold nanoparticles as CT contrast agents.We emphasized the tryout of PEG,gum arabic,gadolinium chelate,and high-density lipoproteins etc.as surfactant to coat gold nanoparticles for CT imaging.We also discussed the existent problems of the newly developed contrast agents and looked forward to the future of them.
  • Related Articles

    [1]WANG Yongsheng, WANG Chensi, LU Haoyu, TIAN Xiangbao, ZHUANG Qixin. Study on the Value of Individualized Contrast Agent Injection Scheme in Improving the Biosafety of Pulmonary Artery CTA[J]. CT Theory and Applications, 2021, 30(6): 777-783. DOI: 10.15953/j.1004-4140.2021.30.06.14
    [2]DONG Xiangyu, FANG Tingsong, YUAN Jianxiang, LIANG Zhenhua, LI Junhong. Discussion on the Effect of Different Concentrations of Contrast Media on CT Imaging of Hepatic Veins Based on BSA and Fixed Iodine Rate[J]. CT Theory and Applications, 2021, 30(4): 466-476. DOI: 10.15953/j.1004-4140.2021.30.04.07
    [3]LI Lu, SHEN Xiaojun, JIE Qian, LIANG Zonghui. The Effect of High Iodine Concentration Contrast Media in Crohn's Disease Patients[J]. CT Theory and Applications, 2020, 29(4): 488-494. DOI: 10.15953/j.1004-4140.2020.29.04.12
    [4]CUI Zhaorui, SHI Zhangzheng, MO Xukai. Meta Analysis of Adenosine Antagonists in the Prevention of Contrast Induced Nephropathy[J]. CT Theory and Applications, 2020, 29(2): 211-218. DOI: 10.15953/j.1004-4140.2020.29.02.12
    [5]MA Zhoupeng, CHEN Bingye, FU Qitian, FU Wenbing, LIN Guansheng. Applicative Research of 3 Different Intestinal Preparation Methods in CT Enterography[J]. CT Theory and Applications, 2019, 28(3): 323-330. DOI: 10.15953/j.1004-4140.2019.28.03.05
    [6]WEN Zhi-qin, MO Xu-kai, SHI Zhang-zheng. Study on Low Contrast Agent Injection Adopted in 320-slice CT Coronary Angiography[J]. CT Theory and Applications, 2018, 27(6): 693-699. DOI: 10.15953/j.1004-4140.2018.27.06.02
    [7]CAO Hong-wei, XING Yuan-yuan, CHOU Heng-zhi, ZHANG Dan, CAO Zhen-dong, WAN Li-ye, WANG Sheng-lin. The Effect of Contrast Medium Injection Rate on the Image Quality of Inferior Vena Cava Direct CTV[J]. CT Theory and Applications, 2017, 26(6): 775-782. DOI: 10.15953/j.1004-4140.2017.26.06.15
    [8]XIA Zhen-ying, QI Zheng, ZHANG Ai-dong, LI Hong-jun, SONG Wen-yan. The Effect of Different Iodine Concentration of Contrast Agent in MSCT Hepatic Arterial Angiography and Its Clinical Application[J]. CT Theory and Applications, 2014, 23(2): 285-292.
    [9]GAO Wen-jie, HUO Jian-wei, DOU Xiu-mei, LI Xia. Ulrich Contrast Medium Injector in 64 Row of Spiral CT Inspection Application[J]. CT Theory and Applications, 2006, 15(3): 50-52.
    [10]Li Ronghuan, Li Jinzhi, Li Xinhua, Zhang Haining, Cui Wenguo. Prevention and Management of Side-effect of Contrast Media in CT Enhancemant Scan[J]. CT Theory and Applications, 2000, 9(3): 20-22.

Catalog

    Article views (1355) PDF downloads (14) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return