Wang Su, Li Peng, Li Li, Zhong Qingjun. Application of HRCT Scan to Repair The Insufficiency of Lacuna Diagnose[J]. CT Theory and Applications, 2001, 10(2): 21-23.
Citation: Wang Su, Li Peng, Li Li, Zhong Qingjun. Application of HRCT Scan to Repair The Insufficiency of Lacuna Diagnose[J]. CT Theory and Applications, 2001, 10(2): 21-23.

Application of HRCT Scan to Repair The Insufficiency of Lacuna Diagnose

More Information
  • Received Date: April 17, 2001
  • Available Online: December 28, 2022
  • Objective: By means of the application of HRCT scanning to increase brain's lacuna diagnoses reliability. Material and methods: Using by HRCT scan clinic doubtful have lacuna patient on floor burl-borough. Barge up against small lacuna-focus with image-plain grain difficult to differentiate, using HRCT scan in homology lay or fluctuation 1-2mm. Result: In 489 rut CT natural cases discover lacuna-focus. In no-easy diagnostic shadiness lacuna-focus 502 cases, using HRCT diagnosed in deed 300 lacuna- focus, bogus lacuna-focus 202 cases, at one time discover HRCT of up to snuff brain -organise-configurable show then rut CT preponderance. Conclusion: HRCT not only can lacuna- infarcted check come out frank, also be able to differentiate false lacuna. This is preferably artifice of reparation a beaten track CT insufficiency of lacuna resolution diagnoses.
  • Related Articles

    [1]YANG Wenhai, ZHANG Guangdong, TAN Zhi, JIN Cong. Study on Forward Numerical Simulation and Instantaneous Seismic Attributes of Natural Gas Hydrate in Permafrost Area[J]. CT Theory and Applications, 2024, 33(1): 25-34. DOI: 10.15953/j.ctta.2023.111
    [2]ZHANG Shi-xin, DU Xiang-dong, HAN Wen-ming, DUAN Jun, SUN Lin-jie. Instantaneous Energy Anomaly Attribute Based on Match Pursuit and its Application in Hydrocarbon Detection of Albertine Graben[J]. CT Theory and Applications, 2015, 24(4): 517-524. DOI: 10.15953/j.1004-4140.2015.24.04.05
    [3]GUO Zhi-min, NI Pei-jun, CAO Yu-ling, QI Zi-cheng, QIAO Ri-dong. Analysis and Evaluation of Two Assessment Techniques for ICT Scanner Spatial Resolution Measurement[J]. CT Theory and Applications, 2015, 24(3): 393-399. DOI: 10.15953/j.1004-4140.2015.24.03.08
    [4]ZHANG Wei-guo, CAO Yu-ling, GUO Zhi-min, NI Pei-jun, ZUO Xin, WANG Xiao-yan, HAO Li-ping. Explore of Different Line-pairs Test Spatial Resolution CT[J]. CT Theory and Applications, 2014, 23(5): 815-820.
    [5]CHEN Jian, HUANG Zheng-ren, LIU Xue-jian, YANG Jin-jing, CHEN Zhong-ming, LIU Yan, YUAN Ming, ZHU Yun-zhou. The Relationship between the Optimal Magnification and the Limit Spatial Resolution in CT System[J]. CT Theory and Applications, 2014, 23(1): 37-43.
    [6]LI Chen, LIU Jie. An Automatic Image Sorting Algorithm for 4D CT Based on Spatial Continuity[J]. CT Theory and Applications, 2012, 21(3): 401-411.
    [7]QUE Jie-min, WANG Yan-fang, LIU Li. Experimental Research on Improving the Spatial Resolution by Using the Method of Pixel Offset Scanning[J]. CT Theory and Applications, 2009, 18(1): 83-87.
    [8]ZHAN Jie, YU Xiao-e. Practice and Study on Automatic Measurement of CT Spatial Resolution[J]. CT Theory and Applications, 2006, 15(2): 43-46.
    [9]WANG Xue-li. Spatial Resolution and Fourier Analysis for X-ray Medical Device[J]. CT Theory and Applications, 2003, 12(4): 36-41.
    [10]WANG Wei-dong, ZHANG Bi-da, CHEN Guang-fei, BAO Shang-lian. Theory and Method of Spatial Encoding in MR Imaging[J]. CT Theory and Applications, 2003, 12(4): 10-16.