ISSN 1004-4140
CN 11-3017/P
Wang Weidong, Bao Shanglian. Basic Theorems and Their Numeric Computation in Image Reconstruction[J]. CT Theory and Applications, 2001, 10(3): 6-9.
Citation: Wang Weidong, Bao Shanglian. Basic Theorems and Their Numeric Computation in Image Reconstruction[J]. CT Theory and Applications, 2001, 10(3): 6-9.

Basic Theorems and Their Numeric Computation in Image Reconstruction

More Information
  • Received Date: February 17, 2001
  • Available Online: December 28, 2022
  • This paper Mathematically present six basic theorems and their numerical computation methods in the field of image reconstruction. With the development of large-scale integral circuits Systolic array the present methods for reconstructing directly images may be implemented real-time. The results of computer simulation are presented for illustrating the efficiency of the proposed methods.
  • Related Articles

    [1]LIU Bicheng, YI Xi, ZONG Chunguang, XU Yanwei, LI Liang. Ring-artifact Correction Method for Large-size Object CT Images Based on Gradient Featured Cluster Analysis[J]. CT Theory and Applications, 2024, 33(6): 781-789. DOI: 10.15953/j.ctta.2024.153
    [2]XU Chi, SHEN Yuwen, SHI Yiqiu, LI Ming, LIU Kefu. Research Progress on Radiology in Spread Through Air Space in Lung Cancer[J]. CT Theory and Applications, 2024, 33(3): 371-376. DOI: 10.15953/j.ctta.2023.140
    [3]LUO Chen, REN Qing, LIU Jianqiang, NIU Tianye. Development of Motion Artifact Correction Solutions for the Cone-beam CT Images during Pancreatic Cancer Image-guided Radiotherapy[J]. CT Theory and Applications, 2022, 31(6): 761-771. DOI: 10.15953/j.ctta.2022.066
    [4]ZHAO Yong-jie, YANG Yong-xin, ZHANG Yong. Development of PET Detector and Scan Structures[J]. CT Theory and Applications, 2014, 23(6): 985-994.
    [5]LI Zhong-chuan, MENG Fan-yong, YANG Min. The Correction of Fan-beam CT Image Artifacts Induced by Deflection of Linear-detectors[J]. CT Theory and Applications, 2014, 23(2): 237-248.
    [6]HUANG Yin-ping, SHEN Bi-xian, CHEN Sheng-ji, ZHOU Na, BAO Lian, CHEN Li-xing. The Research of Comparision between Dual Source CT Air Enema Intestinal Examination and Capsule Endoscopy Small Bowel Examination[J]. CT Theory and Applications, 2010, 19(3): 123-129.
    [7]HU Dong-cai, CHEN Hao, ZHANG Ding-hua. Scatter Correction Method for Flat-Panel Detector-Based Cone Beam CT[J]. CT Theory and Applications, 2009, 18(1): 16-22.
    [8]WANG Ge, Seung WookLee. Grangeat-Type and Katsevich-Type Algorithms for Cone-Beam CT[J]. CT Theory and Applications, 2003, 12(2): 45-55.
    [9]GUO Yi-hua. Diagnostic Value of Annular Enhancement Sign on Enhanced CT Scan in Tuberculoma[J]. CT Theory and Applications, 2002, 11(2): 42-44.
    [10]Xu Weiqing. The Analysis of Ring Artifacts SOMATOM AR[J]. CT Theory and Applications, 2001, 10(1): 36-40.

Catalog

    Article views (688) PDF downloads (5) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return