ISSN 1004-4140
CN 11-3017/P
LI Hai-chao, DING Ke-qin, ZHANG You-chen. Software System Design of CBS Inspection for Penstocks with Insulating Layer[J]. CT Theory and Applications, 2003, 12(2): 6-9.
Citation: LI Hai-chao, DING Ke-qin, ZHANG You-chen. Software System Design of CBS Inspection for Penstocks with Insulating Layer[J]. CT Theory and Applications, 2003, 12(2): 6-9.

Software System Design of CBS Inspection for Penstocks with Insulating Layer

More Information
  • Received Date: April 27, 2003
  • Available Online: December 28, 2022
  • <b<Objective</b< Compton Backscatter Scanning (CBS) Image has the advantage of on-line and positioned in the same side of the object being inspected, which is used widely in aviation and aerospace、customs. <b<Materials and Method</b< This paper introduces the user-oriented inspecting software based on the application of CBS. <b<Result</b< The software includes several modules: Parameters setting、Energy spectra、Scanning measurement、3D image display and Preservation and Print module, etc. <b<Conclusion</b< The master control program has the features of user interface、simply regulation. In this paper, scanned image which has very well display effect is given.
  • Related Articles

    [1]ZHOU Linli, FENG Feng. CT Texture Analysis on the Response Evaluation of Lung Adenocarcinoma Treated by Gifitinib[J]. CT Theory and Applications, 2020, 29(4): 473-480. DOI: 10.15953/j.1004-4140.2020.29.04.10
    [2]XU Yunqian, YUAN Mingdao, CHEN Xiaowen, SHI Yongsheng, LIU Jianwen, YANG Wenbin, LINE Yueqi. Detection Technology of Concealed Structure of Hydraulic Engineering Based on the Fusion of Nondestructive Multi-source Heterogeneous Data[J]. CT Theory and Applications, 2019, 28(2): 187-194. DOI: 10.15953/j.1004-4140.2019.28.02.04
    [3]DU Yu-jing, WANG Rong-fu. Research Progress of PET/CT and New Breakthrough in Axial Field of View[J]. CT Theory and Applications, 2018, 27(5): 675-682. DOI: 10.15953/j.1004-4140.2018.27.05.15
    [4]ZHANG Wei-guo, CAO Yu-ling, GUO Zhi-min, NI Pei-jun, ZUO Xin, WANG Xiao-yan, HAO Li-ping. Explore of Different Line-pairs Test Spatial Resolution CT[J]. CT Theory and Applications, 2014, 23(5): 815-820.
    [5]WANG Peng. The MRS Response of 3D Model in Uniformity Medium[J]. CT Theory and Applications, 2014, 23(4): 569-578.
    [6]LIU Liang, ZHANG Bin, PAN Jin-xiao. An Improved FBP Arithmetic Based on Detector’s Width[J]. CT Theory and Applications, 2007, 16(1): 54-59.
    [7]LI Liang, CHEN Zhi-qiang, ZHANG Li, XING Yu-xiang, KANG Ke-jun. A BPF-type Reconstruction Algorithm for Cone-beam CT System with a Reduced Size Detector[J]. CT Theory and Applications, 2007, 16(1): 1-9.
    [8]CHEN Zhi-qiang, LI Liang, KANG Ke-jun, ZHANG Li. New Developments of exact Cone-beam CT Reconstruction Algorithms[J]. CT Theory and Applications, 2005, 14(3): 65-70.
    [9]ZENG Xiang-zhao. Structure and Standard of Image Resolution Test Card[J]. CT Theory and Applications, 2005, 14(3): 29-34.
    [10]DING Ke-qin, DING Hou-ben. Study on CBS On-line Inspection Apparatus of Pressure Pipeline with the Insulation[J]. CT Theory and Applications, 2004, 13(4): 26-30.