ISSN 1004-4140
CN 11-3017/P
FANG Quan, FANG Zheng, ZHONG Ai-jun, LUO Qing-ming, GONG Hui. Adjusting of Cone-beam X-ray Source of Micro CT[J]. CT Theory and Applications, 2006, 15(2): 69-73.
Citation: FANG Quan, FANG Zheng, ZHONG Ai-jun, LUO Qing-ming, GONG Hui. Adjusting of Cone-beam X-ray Source of Micro CT[J]. CT Theory and Applications, 2006, 15(2): 69-73.

Adjusting of Cone-beam X-ray Source of Micro CT

More Information
  • Received Date: March 19, 2006
  • Available Online: December 16, 2022
  • Accurate coordinate of X-ray source is one of the key parameters in design of micro CT based on cone-beam X-ray system. The method of calculating the coordinate of X-ray source through a metallic ball model's 2-D projections is represented. It is based on micro source system which the source is counted as a particle under a certain amplification. Coordinate of the source could be calculated through projective lines. Avoiding the micro CT system is fixed, cone-beam reconstruction formulas with a nonstationary shift of X-ray source are represented. Model test are performed to show the effect after corrected for the shift of X-ray source.
  • Related Articles

    [1]LUAN Minglong, LIU Zeng, LIU Aiyou, WEI Dingyong, SUN Xuesong. The Application of Natural Source Surface Wave Technology in Urban Engineering Investigation[J]. CT Theory and Applications, 2020, 29(6): 651-662. DOI: 10.15953/j.1004-4140.2020.29.06.03
    [2]PAN Jishun, SUN Kaixuan, ZHANG Niu, LI Penghui. Non-SIRT Engineering Seismic Wave CT Technology[J]. CT Theory and Applications, 2020, 29(2): 119-127. DOI: 10.15953/j.1004-4140.2020.29.02.01
    [3]XU Yunqian, YUAN Mingdao, CHEN Xiaowen, SHI Yongsheng, LIU Jianwen, YANG Wenbin, LINE Yueqi. Detection Technology of Concealed Structure of Hydraulic Engineering Based on the Fusion of Nondestructive Multi-source Heterogeneous Data[J]. CT Theory and Applications, 2019, 28(2): 187-194. DOI: 10.15953/j.1004-4140.2019.28.02.04
    [4]CHEN Si, LI Jing, LI Shi-gen, LI Shou-tao, CHEN Yun-bin, ZHANG Xiao-li. A Registration and Evaluation Algorithm for the Calibration of Point Extraction Precision Based on ICT Equipment[J]. CT Theory and Applications, 2016, 25(6): 671-678. DOI: 10.15953/j.1004-4140.2016.25.06.07
    [5]SONG Xi-yu, YAN Bin, ZHOU Li-li, CHEN Jian, CENG Lei, QIAO Kai, HU Fa-zong. Application of 3D Printing Technology in the Field of CT Technology[J]. CT Theory and Applications, 2015, 24(1): 57-68. DOI: 10.15953/j.1004-4140.2015.24.01.07
    [6]XU Shun-qiang, LIU Wen-chao, LI Qing-lin, CHEN Zhi-guo, WANG Shi, QIN Jian-zeng, HE Yong-bo. Application of 3D High Density Resistivity Tomography in Engineering Detection of Complex Condition[J]. CT Theory and Applications, 2011, 20(1): 39-46.
    [7]SUN Ming-tai, LIANG Yue-xuan, HU Zhu-xi, XU Jian-hua. Study on the Application of ICT to Structure Analysis and Dismantle in the Aerial Depth Bomb[J]. CT Theory and Applications, 2008, 17(1): 50-55.
    [8]WANG Yan-fang, LIU Li, QUE Jie-min, YAN Yong-lian. Obtainment of the Geometrical Parameters of Two Dimensional Contour in Reverse Engineering based on Industrial Computerized Tomography[J]. CT Theory and Applications, 2007, 16(3): 29-35.
    [9]DING Guo-fu. Application of high Energy Industrial Computed Tomography In Testing Solid Rocket Engine[J]. CT Theory and Applications, 2005, 14(3): 35-39.
    [10]WANG Yan-fang, QUE Jie-min, LIU Li, ZENG Gang. A Software of Reverse Engineering Based on Industrial CT[J]. CT Theory and Applications, 2004, 13(3): 39-42.

Catalog

    Article views (591) PDF downloads (13) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return