Resistivity Tomography of Buried Cavities at the Construction Site Along River

More Information
  • Received Date: May 07, 2006
  • Available Online: December 16, 2022
  • The building site developed along the river in Sanmenxia city of province Henan; The construction site surveyed by 2D Resistivity Tomography method. The exact locations, buried depths, water-bearing states and size of the cavities were found out, which indicate that 2D Resistivity Tomography surrey is an effectual method in practice for probing the buried cavities. If there is no water in the cavity, the anomaly would appear as a closed circle with high impedance in the 2D resistivity image. In contrast, the anomaly would manifested as a closed circle with bow impedance if there is water in the cavity.
  • Related Articles

    [1]JI Wenchao, TIAN Weili, LIU Wenya, HE Lianghao, YANG Jian. Application of the Canon 320 Row Variable Helical Pitch CTA System Combined with Iterative Reconstruction Technology for Lower Limb Vascular Imaging[J]. CT Theory and Applications, 2025, 34(1): 149-154. DOI: 10.15953/j.ctta.2024.009
    [2]XIE Ruigang, WANG Siyan, AN Hengbin, SU Tao, SUN Minghua. Impact of Electrocardiogram Gating Technology on Radiation Dose in Dual-source Computed Tomography High Pitch Spiral Scanning Using a Phantom[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.300
    [3]WANG Chensi, HONG Yao, FANG Huimin, DING Xuelu, YANG Yifan, TIAN Xiangbao, CHEN Wenjing, WANG Yongsheng. Based on the Effect of Different Pitches on Neck CTA Radiation Dose and Image Quality under Automatic Tube Current Modulation Technology[J]. CT Theory and Applications, 2024, 33(3): 309-315. DOI: 10.15953/j.ctta.2023.148
    [4]LIU Dandan, LI Wei, ZHANG Yongxian, ZHAO Bo, CUI Ying, KANG Tianliang, MA Zixuan, LIU Yuhang, NIU Yantao. Preliminary exploration of non-gated high-pitch chest CT combined with artificial intelligence in assessing coronary artery calcium score[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.085
    [5]YANG Zhengjun, ZHANG Ang, CHEN Yong, JIANG Jiang, WANG Lingyun, ZHANG Yong, ZHANG Xuan, QI Xiaofeng. The Effect of Radiation Dose and Tube Potential on Image Quality of CT: A Task-based Image Quality Assessment[J]. CT Theory and Applications, 2022, 31(2): 211-217. DOI: 10.15953/j.ctta.2021.060
    [6]WU Tenghui, ZHA Yunfei, YANG Feng. The Study of Application of Different Pitch Combined with ASIR in Low-dose Chest CT Screening on COVID-19[J]. CT Theory and Applications, 2022, 31(2): 186-194. DOI: 10.15953/j.1004-4140.2022.31.02.05
    [7]GUO Wei-ya, LIU Yi-jun, LIU Ai-lian. To Explore the Influence of GSI Data of Standard Model in Different Pitch of Single Source-dual Energy CT[J]. CT Theory and Applications, 2017, 26(3): 279-284. DOI: 10.15953/j.1004-4140.2017.26.03.03
    [8]BAO Li-wei, WANG Ze-feng, SUN Zhen-ting, MENG Ling-xin, ZHAO Lei. Evaluation of Image Quality and Radiation Dose for Low-tube Voltage Head and Neck CTA[J]. CT Theory and Applications, 2015, 24(1): 87-94. DOI: 10.15953/j.1004-4140.2015.24.01.10
    [9]FU Chuan-ming, WU De-hong, XU Lin, CHEN Lun-gang, WANG Zhong-ping, XIONG Yin. Reduce the Radiation Dose in the Lower Extremities to Explore the Feasibility of CTA[J]. CT Theory and Applications, 2014, 23(3): 467-473.
    [10]ZHOU Ze-jun, HU Yong-sheng, GAO Bin, CHAO Hui-ming. Expounding the Pitch,Thickness,Reconstructing Space of Multislice CT and Influencing the Imaging Quality[J]. CT Theory and Applications, 2008, 17(1): 21-26.

Catalog

    Article views (681) PDF downloads (1) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return