ISSN 1004-4140
CN 11-3017/P
WANG Fang-jun, CHEN Wei-chang, GUO Liang, FANG Xiang-ming, LIU Peng-fei. The Study to the Multisection Dynamic CT Perfusion on Normal Pancreas[J]. CT Theory and Applications, 2009, 18(2): 83-91.
Citation: WANG Fang-jun, CHEN Wei-chang, GUO Liang, FANG Xiang-ming, LIU Peng-fei. The Study to the Multisection Dynamic CT Perfusion on Normal Pancreas[J]. CT Theory and Applications, 2009, 18(2): 83-91.

The Study to the Multisection Dynamic CT Perfusion on Normal Pancreas

More Information
  • Received Date: December 25, 2008
  • Available Online: December 14, 2022
  • To quantitative analysis and assess the blood perfusion characteristic of normal pancreas by Multisection dynamic CT.To investigate the perfusion parameters's change according to age, sex and difference locations of normal pancreas.30 cases with normal pancreas were examined for pancreatic perfusion and was divided into three sub-group according to age.The multisection dynamic CT perfusion series was performed for pancreatic perfusion on a multisection CT scanner(Siemens somatom Sensation 64), 120 kV, 100 mA.Contrast injection was done by using 50 mL nonionic contrast agent(300 mgI/mL), at a flow rate of 5 mL/s with a power injector, and 6 seconds delay.The data acquisition lasted for 30 seconds.These datas were processed on a SIEMENS workstation using PCT software package, and the mean Fb,Vb,Ttp and PS were measured and statistically analyzed in 30 cases with normal pancreas.The study showed that all perfusion parameters didn't influenced by age, sex and difference locations of pancreas(P>0.05).The mean Fb,Vb,Ttp and PS in normal pancreas tissue were 133.55 ±25.70(mL/100mL/min), 193.78 ±27.01(mL/L), 142.41 ±13.95(0.1 s), 128.72 ±34.53(0.5 mL/100mL/min), respectively.The perfusion parameters in three sub-group according to age were not statistically significant(P>0.05).The mean Fb,Vb,Ttp and PS in pancreas of male were 127.59 ±22.90(mL/100mL/min), 188.72 ±25.19(mL/L), 142.91 ±13.17(0.1 s), 133.30 ±42.86(0.5 mL/100mL/min), respectively and those parameters of female were 142.48 ±28.04(mL/100mL/min), 201.37 ±28.94(mL/L), 141.66 ±15.63(0.1 s), 121.85 ±14.80(0.5 mL/100mL/min), respectively.The perfusion parameters in male and female were not statistically significant(P>0.05).The perfusion parameters in difference locations of pancreas were also not statistically significant(P>0.05).MSCT perfusion imaging may reflect the features of normal pancreatic perfusion.All of perfusion parameters didn't influenced by age, sex and difference positions of pancreas.
  • Related Articles

    [1]HUO Meng, LI Ling, SUN Ying, ZHANG Mingxia, SUN Lei, GUO Jia, DU Changyue, LI Xingpeng, HAO Qi, ZHANG Yan, DUAN Shuhong, LIU Xiaoyan, LIU Wei, DUAN Yongli, ZHANG Chunyan, WANG Rengui. Analysis of Coronavirus Disease 2019 Chest High-resolution Computed Tomography Manifestations between Groups with Different Neutrophil- to-Lymphocyte Ratios[J]. CT Theory and Applications, 2023, 32(3): 387-394. DOI: 10.15953/j.ctta.2023.027
    [2]WANG Runhua, WANG Haipeng, LI Jianli, WANG Jinxiu, LI Kunjie, Y. S. Yang. Characterization of Pore Distribution of the Anthracite Coal Sample Based on Synchrotron Radiation X-ray CT[J]. CT Theory and Applications, 2021, 30(6): 691-700. DOI: 10.15953/j.1004-4140.2021.30.06.04
    [3]DING Weihua, ZHU Lin, HUANG Li, ZHANG Le, QIN Junrong, LI Aiguo. Study on Concrete Mesoscopic Damage Under Dynamic Loading Using CT Image Segmentation and Gray Level Co-occurrence Matrix Eigenvalue[J]. CT Theory and Applications, 2021, 30(2): 170-182. DOI: 10.15953/j.1004-4140.2021.30.02.04
    [4]QIAO Penggang, WEI Jiaotong, PAN Jinxiao. Calculation of Aluminum Foam Porosity Based on Multi-spectrum CT and NC-POCS Reconstruction Algorithm[J]. CT Theory and Applications, 2021, 30(1): 71-80. DOI: 10.15953/j.1004-4140.2021.30.01.07
    [5]YU Qian-qian, LI Zhen-chun, ZHANG Min, ZHANG Kai, YU Zhen-nan, ZHANG Xin, PAN Dong. The Study of Seismic Attenuation Tomography Inversion Based on Spectrum Ratio Method[J]. CT Theory and Applications, 2017, 26(5): 533-541. DOI: 10.15953/j.1004-4140.2017.26.05.01
    [6]HAO Nai, MAO Ling-tao, WEI Feng, MA Jia-nian. Experimental Study on Coal Associated with Carbon Dioxide Sorption by CT[J]. CT Theory and Applications, 2014, 23(3): 425-433.
    [7]YANG Xue-hai, ZHANG Wei-bin, DAI Bin, TIAN Yong, YANG Cun-feng. Research on Energy Material Eensity by X-ray Micro Computed Tomography[J]. CT Theory and Applications, 2009, 18(4): 61-67.
    [8]LI Jian-ying. Technique Advancements of Light Speed VCT and Its Clinical Applications[J]. CT Theory and Applications, 2007, 16(2): 60-65.
    [9]CENG Liang, LI Zhen-yu, WANG Peng. Improveing S/N Ratio of MRS Signal of Detecting Ground Water with Wavelet Analysis[J]. CT Theory and Applications, 2006, 15(2): 1-5.
    [10]Cao Yuling, Sun Lingxia. Applications of Industry CT in Porosity Analysis of Composite Material[J]. CT Theory and Applications, 2001, 10(4): 14-17.

Catalog

    Article views (640) PDF downloads (2) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return