The Sinus Image of Reduction Dose in Children with Spiral CT

More Information
  • Received Date: December 22, 2008
  • Available Online: December 14, 2022
  • Objective:To reduce radiation dose and ensure sinus image quality in children with optimizing tube current.Materials and Methods:80 children were randomly divided into standard dose group and three low dose groups, in which tube voltage was constantly 120kV and tube current were 350mA, 235mA, 175mA, and125mA, respectively.The mean DLP and ED of each group were measured, compared with mean ED in standard dose group, and then decrease of ED in three low dose groups were calculated separately.The image quality in all groups was blindly evaluated.Results:Compared with standard dose group, ED of other three groups decreased by 23.9%, 42.7%, and 60.2%, respectively.For image quality in all groups, there were no differences found.All sinus images reached desired diagnostic quality.Conclusion:With reduced tube current of 125mA, low dose CT of sinuses in children can yield diagnostic image quality;further radiation dose are reduced about 60%.
  • Related Articles

    [1]XIANG Ronglin, ZHANG Li. Suppression Method for Cone-Beam CT Artifact Based on FDK Compensation and Dual-Source Weighting[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.222
    [2]XU Tongjiang, WANG Xu, LI Yan, DENG Gang, LIU Jianxin, YIN Xiaoming, LIANG Weizhong, WU Ge. Application of IMR, iDose<sup<4</sup< and FBP Reconstruction Algorithms in CT Scanning of Rhinoplasty[J]. CT Theory and Applications, 2022, 31(3): 357-364. DOI: 10.15953/j.ctta.2021.072
    [3]LV Zhentao, GUI Zhiguo, LIU Yi, ZHANG Pengcheng. Industrial CT Rotation Center Calibration Method Based on Weighted Average[J]. CT Theory and Applications, 2021, 30(5): 539-546. DOI: 10.15953/j.1004-4140.2021.30.05.01
    [4]WANG Jing-yu, HAN Yu, LI Lei, XI Xiao-qi, SUN Yan-min, YAN Bin. A Novel Reconstruction Algorithm Based-on Projection Transformation for the Rotational Cone-beam CL[J]. CT Theory and Applications, 2017, 26(5): 575-582. DOI: 10.15953/j.1004-4140.2017.26.05.06
    [5]YUAN Ye, HUANG Xiao-han, WANG Zhong-gang, ZHANG Yu, JIANG Zheng. The Method of Inversion Imaging Based on Matrix Pretreatment and BPT-SIRT Nonlinear Weighted[J]. CT Theory and Applications, 2017, 26(1): 53-62. DOI: 10.15953/j.1004-4140.2017.26.01.07
    [6]HU Jun-jie, MA Chen-xin, YAN Bin. Optimization of Filter Function in CT Image Reconstruction[J]. CT Theory and Applications, 2013, 22(1): 85-92.
    [7]LIU Liang, ZHANG Bin, PAN Jin-xiao. An Improved FBP Arithmetic Based on Detector’s Width[J]. CT Theory and Applications, 2007, 16(1): 54-59.
    [8]YUAN Ming-kai, LIU Li. Comparative Analysis of FBP and OSEM Reconstruction Methods in Industrial CT[J]. CT Theory and Applications, 2006, 15(1): 56-60.
    [9]CHEN Zhi-qiang, LI Liang, KANG Ke-jun, ZHANG Li. New Developments of exact Cone-beam CT Reconstruction Algorithms[J]. CT Theory and Applications, 2005, 14(3): 65-70.
    [10]LIU Li, WU Xiao-feng, YIN Yin. Positron Emission Tomography and PET Image Reconstruction[J]. CT Theory and Applications, 2003, 12(1): 47-50.

Catalog

    Article views PDF downloads Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return