Research of Tomography's Application in Multiphase Flow Measurement

More Information
  • Received Date: August 04, 2008
  • Available Online: December 14, 2022
  • On the basis of analyzing all kinds of tomography fundamental and its advantage and disadvantage, a new multiphase flow detection technique-an electrical impedance tomography is introduced, and a new algorithm used in EIT image reconstruction is proposed.This algorithm will improve the convergence speed and the quality of the image reconstruction by using the method of mixed genetic algorithm and landweber iteration algorithm.The experimental results show that the EIT system is an effective system for multiphase flow measurement, the algorithm has the advantage of good convergence stability and rapid convergence rate.
  • Related Articles

    [1]XIANG Ronglin, ZHANG Li. Suppression Method for Cone-Beam CT Artifact Based on FDK Compensation and Dual-Source Weighting[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.222
    [2]XU Tongjiang, WANG Xu, LI Yan, DENG Gang, LIU Jianxin, YIN Xiaoming, LIANG Weizhong, WU Ge. Application of IMR, iDose<sup<4</sup< and FBP Reconstruction Algorithms in CT Scanning of Rhinoplasty[J]. CT Theory and Applications, 2022, 31(3): 357-364. DOI: 10.15953/j.ctta.2021.072
    [3]LV Zhentao, GUI Zhiguo, LIU Yi, ZHANG Pengcheng. Industrial CT Rotation Center Calibration Method Based on Weighted Average[J]. CT Theory and Applications, 2021, 30(5): 539-546. DOI: 10.15953/j.1004-4140.2021.30.05.01
    [4]WANG Jing-yu, HAN Yu, LI Lei, XI Xiao-qi, SUN Yan-min, YAN Bin. A Novel Reconstruction Algorithm Based-on Projection Transformation for the Rotational Cone-beam CL[J]. CT Theory and Applications, 2017, 26(5): 575-582. DOI: 10.15953/j.1004-4140.2017.26.05.06
    [5]YUAN Ye, HUANG Xiao-han, WANG Zhong-gang, ZHANG Yu, JIANG Zheng. The Method of Inversion Imaging Based on Matrix Pretreatment and BPT-SIRT Nonlinear Weighted[J]. CT Theory and Applications, 2017, 26(1): 53-62. DOI: 10.15953/j.1004-4140.2017.26.01.07
    [6]HU Jun-jie, MA Chen-xin, YAN Bin. Optimization of Filter Function in CT Image Reconstruction[J]. CT Theory and Applications, 2013, 22(1): 85-92.
    [7]LIU Liang, ZHANG Bin, PAN Jin-xiao. An Improved FBP Arithmetic Based on Detector’s Width[J]. CT Theory and Applications, 2007, 16(1): 54-59.
    [8]YUAN Ming-kai, LIU Li. Comparative Analysis of FBP and OSEM Reconstruction Methods in Industrial CT[J]. CT Theory and Applications, 2006, 15(1): 56-60.
    [9]CHEN Zhi-qiang, LI Liang, KANG Ke-jun, ZHANG Li. New Developments of exact Cone-beam CT Reconstruction Algorithms[J]. CT Theory and Applications, 2005, 14(3): 65-70.
    [10]LIU Li, WU Xiao-feng, YIN Yin. Positron Emission Tomography and PET Image Reconstruction[J]. CT Theory and Applications, 2003, 12(1): 47-50.

Catalog

    Article views (586) PDF downloads (3) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return