ISSN 1004-4140
CN 11-3017/P
GAO Jie, TAN Mao-jin, ZHONG Guang-hai, LIU Huan-li. Resolution Matching Method of High Induction Logging and Applications[J]. CT Theory and Applications, 2009, 18(2): 41-49.
Citation: GAO Jie, TAN Mao-jin, ZHONG Guang-hai, LIU Huan-li. Resolution Matching Method of High Induction Logging and Applications[J]. CT Theory and Applications, 2009, 18(2): 41-49.

Resolution Matching Method of High Induction Logging and Applications

More Information
  • Received Date: April 02, 2009
  • Available Online: December 14, 2022
  • High resolution processing of logs is of great significance to logging formation evaluation in thin beds.Russian High Induction Logging(HIL) tool has been applied in China, but one of main problems is that the resolution of its four curves does not match each other.On the basis of the information compensation theory of the induction logging and the analysis of investigation characteristics of HIL, the method of resolution matching and processing technology have been obtained.The results derived from the assumed formation model and some practical cases show that the resolution matching method is reliable and the processed data in situ is reasonable.
  • Related Articles

    [1]HAN Song, LIU Yanli, PENG Haotian, CHEN Hongfan, ZENG Ming, ZHANG Shurui. Q-Compensation for Near Surface with Low-Frequency Protection and Its Application in Prestack Processing of Central Sichuan Basin[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.298
    [2]GUO Zhi-min, NI Pei-jun, CAO Yu-ling, QI Zi-cheng, QIAO Ri-dong. Analysis and Evaluation of Two Assessment Techniques for ICT Scanner Spatial Resolution Measurement[J]. CT Theory and Applications, 2015, 24(3): 393-399. DOI: 10.15953/j.1004-4140.2015.24.03.08
    [3]ZHANG Wei-guo, CAO Yu-ling, GUO Zhi-min, NI Pei-jun, ZUO Xin, WANG Xiao-yan, HAO Li-ping. Explore of Different Line-pairs Test Spatial Resolution CT[J]. CT Theory and Applications, 2014, 23(5): 815-820.
    [4]ZHANG Ming-xia, WANG Ren-gui. Preliminary Study of Diagnostic Value of Ultra High Resolution Thin Slice CT on Small Pulmonary Nodules Diameter Less Than 2cm[J]. CT Theory and Applications, 2014, 23(1): 123-130.
    [5]FENG Mei, AN Mei-jian. How to Determine Spatial Resolution for an Inverse Problem[J]. CT Theory and Applications, 2013, 22(4): 587-604.
    [6]ZHANG Jun-sheng, WANG Ming-quan, GUO Yong-liang, CHEN Zhi-qiang. Analysis of X-ray Digital Imaging System Resolution[J]. CT Theory and Applications, 2011, 20(2): 227-234.
    [7]QUE Jie-min, WANG Yan-fang, LIU Li. Experimental Research on Improving the Spatial Resolution by Using the Method of Pixel Offset Scanning[J]. CT Theory and Applications, 2009, 18(1): 83-87.
    [8]ZENG Xiang-zhao. Structure and Standard of Image Resolution Test Card[J]. CT Theory and Applications, 2005, 14(3): 29-34.
    [9]WANG Xue-li. Spatial Resolution and Fourier Analysis for X-ray Medical Device[J]. CT Theory and Applications, 2003, 12(4): 36-41.
    [10]CHEN Wei-chang, CHEN Zhi-hua, ZHAO Tian-de, WANG Zi-qiang. Improvement of CT Contrast (Density) Resolution By Dual Photons Absorption Method[J]. CT Theory and Applications, 2002, 11(4): 5-8.

Catalog

    Article views (611) PDF downloads (3) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return