ISSN 1004-4140
CN 11-3017/P
LI Shou-tao, CHEN Hao, ZHU Rui-hui, LI Xiao-mao. Application of CV Active Contour in Weld Defects Detection[J]. CT Theory and Applications, 2008, 17(4): 55-61.
Citation: LI Shou-tao, CHEN Hao, ZHU Rui-hui, LI Xiao-mao. Application of CV Active Contour in Weld Defects Detection[J]. CT Theory and Applications, 2008, 17(4): 55-61.

Application of CV Active Contour in Weld Defects Detection

More Information
  • Received Date: August 28, 2008
  • Available Online: December 14, 2022
  • Weld is the main way of constructing steel structure.X ray detection is one of the few major techniques in detecting weld defects.There are two methods for evaluating the results of X ray detection: manually and automatically evaluation.In a manual way,the person may be tired so the result is not reliable,and the evaluation is subjective.The computer aided analysis and recognition can improve the efficiency.The basis of analysis and recognition is image segmentation.This article is based on CV model which is an development of Mumford-Shah model and active contour by Tony,Chan and Luminita.And we apply this model in welding seam defects detection.
  • Related Articles

    [1]YANG Wenhai, ZHANG Guangdong, TAN Zhi, JIN Cong. Study on Forward Numerical Simulation and Instantaneous Seismic Attributes of Natural Gas Hydrate in Permafrost Area[J]. CT Theory and Applications, 2024, 33(1): 25-34. DOI: 10.15953/j.ctta.2023.111
    [2]ZHANG Shi-xin, DU Xiang-dong, HAN Wen-ming, DUAN Jun, SUN Lin-jie. Instantaneous Energy Anomaly Attribute Based on Match Pursuit and its Application in Hydrocarbon Detection of Albertine Graben[J]. CT Theory and Applications, 2015, 24(4): 517-524. DOI: 10.15953/j.1004-4140.2015.24.04.05
    [3]GUO Zhi-min, NI Pei-jun, CAO Yu-ling, QI Zi-cheng, QIAO Ri-dong. Analysis and Evaluation of Two Assessment Techniques for ICT Scanner Spatial Resolution Measurement[J]. CT Theory and Applications, 2015, 24(3): 393-399. DOI: 10.15953/j.1004-4140.2015.24.03.08
    [4]ZHANG Wei-guo, CAO Yu-ling, GUO Zhi-min, NI Pei-jun, ZUO Xin, WANG Xiao-yan, HAO Li-ping. Explore of Different Line-pairs Test Spatial Resolution CT[J]. CT Theory and Applications, 2014, 23(5): 815-820.
    [5]CHEN Jian, HUANG Zheng-ren, LIU Xue-jian, YANG Jin-jing, CHEN Zhong-ming, LIU Yan, YUAN Ming, ZHU Yun-zhou. The Relationship between the Optimal Magnification and the Limit Spatial Resolution in CT System[J]. CT Theory and Applications, 2014, 23(1): 37-43.
    [6]LI Chen, LIU Jie. An Automatic Image Sorting Algorithm for 4D CT Based on Spatial Continuity[J]. CT Theory and Applications, 2012, 21(3): 401-411.
    [7]QUE Jie-min, WANG Yan-fang, LIU Li. Experimental Research on Improving the Spatial Resolution by Using the Method of Pixel Offset Scanning[J]. CT Theory and Applications, 2009, 18(1): 83-87.
    [8]ZHAN Jie, YU Xiao-e. Practice and Study on Automatic Measurement of CT Spatial Resolution[J]. CT Theory and Applications, 2006, 15(2): 43-46.
    [9]WANG Xue-li. Spatial Resolution and Fourier Analysis for X-ray Medical Device[J]. CT Theory and Applications, 2003, 12(4): 36-41.
    [10]WANG Wei-dong, ZHANG Bi-da, CHEN Guang-fei, BAO Shang-lian. Theory and Method of Spatial Encoding in MR Imaging[J]. CT Theory and Applications, 2003, 12(4): 10-16.

Catalog

    Article views (987) PDF downloads (3) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return