ISSN 1004-4140
CN 11-3017/P
JIANG Rui-zhi, YUE Xiu-yan, SHI Ting-chun, QIU Jian-hui, SUO Hai-rui, PENG Dong-liang. Overview of RP-Oriented CT Image Processing Technology[J]. CT Theory and Applications, 2008, 17(1): 14-20.
Citation: JIANG Rui-zhi, YUE Xiu-yan, SHI Ting-chun, QIU Jian-hui, SUO Hai-rui, PENG Dong-liang. Overview of RP-Oriented CT Image Processing Technology[J]. CT Theory and Applications, 2008, 17(1): 14-20.

Overview of RP-Oriented CT Image Processing Technology

More Information
  • Received Date: November 13, 2007
  • Available Online: December 14, 2022
  • Data modeling in reverse engineering is one of key technologies to realize RP. According to the 2D information of CT image, the edge contour was extracted by the image segmentation and binary image processing. Then the 3D CAD model was reconstructed. 3D physical model was made by reconstructing the 3D CAD model, converting into standard data for RP. It has wide application in the biomedicine domain. Based on the state of the study, the process of CT image reverse model and its application on RP were discussed.
  • Related Articles

    [1]XIANG Ronglin, ZHANG Li. Suppression Method for Cone-Beam CT Artifact Based on FDK Compensation and Dual-Source Weighting[J]. CT Theory and Applications. DOI: 10.15953/j.ctta.2024.222
    [2]XU Tongjiang, WANG Xu, LI Yan, DENG Gang, LIU Jianxin, YIN Xiaoming, LIANG Weizhong, WU Ge. Application of IMR, iDose<sup<4</sup< and FBP Reconstruction Algorithms in CT Scanning of Rhinoplasty[J]. CT Theory and Applications, 2022, 31(3): 357-364. DOI: 10.15953/j.ctta.2021.072
    [3]LV Zhentao, GUI Zhiguo, LIU Yi, ZHANG Pengcheng. Industrial CT Rotation Center Calibration Method Based on Weighted Average[J]. CT Theory and Applications, 2021, 30(5): 539-546. DOI: 10.15953/j.1004-4140.2021.30.05.01
    [4]WANG Jing-yu, HAN Yu, LI Lei, XI Xiao-qi, SUN Yan-min, YAN Bin. A Novel Reconstruction Algorithm Based-on Projection Transformation for the Rotational Cone-beam CL[J]. CT Theory and Applications, 2017, 26(5): 575-582. DOI: 10.15953/j.1004-4140.2017.26.05.06
    [5]YUAN Ye, HUANG Xiao-han, WANG Zhong-gang, ZHANG Yu, JIANG Zheng. The Method of Inversion Imaging Based on Matrix Pretreatment and BPT-SIRT Nonlinear Weighted[J]. CT Theory and Applications, 2017, 26(1): 53-62. DOI: 10.15953/j.1004-4140.2017.26.01.07
    [6]HU Jun-jie, MA Chen-xin, YAN Bin. Optimization of Filter Function in CT Image Reconstruction[J]. CT Theory and Applications, 2013, 22(1): 85-92.
    [7]LIU Liang, ZHANG Bin, PAN Jin-xiao. An Improved FBP Arithmetic Based on Detector’s Width[J]. CT Theory and Applications, 2007, 16(1): 54-59.
    [8]YUAN Ming-kai, LIU Li. Comparative Analysis of FBP and OSEM Reconstruction Methods in Industrial CT[J]. CT Theory and Applications, 2006, 15(1): 56-60.
    [9]CHEN Zhi-qiang, LI Liang, KANG Ke-jun, ZHANG Li. New Developments of exact Cone-beam CT Reconstruction Algorithms[J]. CT Theory and Applications, 2005, 14(3): 65-70.
    [10]LIU Li, WU Xiao-feng, YIN Yin. Positron Emission Tomography and PET Image Reconstruction[J]. CT Theory and Applications, 2003, 12(1): 47-50.

Catalog

    Article views PDF downloads Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return