ISSN 1004-4140
    CN 11-3017/P
    ZHANG Yinyang, ZHU Mengmeng, XU Feng, BIAN Guangli, BAO Lei, CHENG Chen, QIU Li. Value of a Logistic Regression Model that Combines Non-Contrast Chest CT and Ultrasound Features for Differentiating Benign and Malignant Breast MassesJ. CT Theory and Applications. DOI: 10.15953/j.ctta.2026.239
    Citation: ZHANG Yinyang, ZHU Mengmeng, XU Feng, BIAN Guangli, BAO Lei, CHENG Chen, QIU Li. Value of a Logistic Regression Model that Combines Non-Contrast Chest CT and Ultrasound Features for Differentiating Benign and Malignant Breast MassesJ. CT Theory and Applications. DOI: 10.15953/j.ctta.2026.239

    Value of a Logistic Regression Model that Combines Non-Contrast Chest CT and Ultrasound Features for Differentiating Benign and Malignant Breast Masses

    • Objective: In this study, we aimed to evaluate the value of a logistic regression model that combines non-contrast chest multi-slice spiral computed tomography (MSCT) and breast ultrasound features for differentiating benign and malignant breast masses. Methods: In total, 288 patients with pathologically confirmed incidental breast masses detected on routine chest computed tomography (CT) were retrospectively included. Of these patients, 216 had benign and 72 had malignant masses. Data on CT attenuation, low-attenuation component, axillary lymph node status, ultrasound Breast Imaging Reporting and Data System (BI-RADS) category, and ultrasound morphology were extracted. Opportunistic CT, ultrasound, and combined CT–ultrasound logistic regression models were developed and evaluated using receiver operating characteristic (ROC) curve analysis, calibration assessment, decision curve analysis, and repeated stratified cross-validation. Discrimination was assessed using the area under the ROC curve (AUC). Results: CT attenuation, a low-attenuation component, an axillary lymph node short-axis diameter ≥10 mm, the ultrasound BI-RADS category, and an irregular ultrasound shape were associated with malignancy. The AUCs were 0.820 (95% confidence interval CI, 0.761–0.874) for the opportunistic CT model, 0.855 (95% CI, 0.795–0.908) for the ultrasound model and 0.921 (95% CI, 0.886–0.953) for the combined logistic regression model. The combined logistic regression model improved the AUC by 0.102 and 0.066 compared with the CT and ultrasound models, respectively, with the differences being significant after Holm correction (adjusted P = 0.0008 and 0.0006). At the optimal Youden threshold, the combined model achieved a sensitivity of 0.903, specificity of 0.782, and negative predictive value of 0.960. Decision curve analysis showed that the combined model provided a higher net benefit at threshold probabilities of approximately 0.10–0.33. Conclusion: Non-contrast chest CT provides supplementary information for ultrasound-based assessments of breast masses. The combined logistic regression model incorporating CT attenuation, the low-attenuation component, axillary lymph node status, and ultrasound features showed good internally validated diagnostic performance. However, external validation is still required.
    • loading

    Catalog

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return