ISSN 1004-4140
CN 11-3017/P
苗娜, 齐旭红, 杜常月, 陈世光, 毕冬梅, 温智勇. 胸部MSCT在致密型乳腺肿块诊断中的应用价值[J]. CT理论与应用研究, 2020, 29(1): 79-88. DOI: 10.15953/j.1004-4140.2020.29.01.10
引用本文: 苗娜, 齐旭红, 杜常月, 陈世光, 毕冬梅, 温智勇. 胸部MSCT在致密型乳腺肿块诊断中的应用价值[J]. CT理论与应用研究, 2020, 29(1): 79-88. DOI: 10.15953/j.1004-4140.2020.29.01.10
MIAO Na, QI Xuhong, DU Changyue, CHEN Shiguang, BI Dongmei, WEN Zhiyong. The Application Value of Chest Multi-slice Spiral CT in the Diagnosis of Mass in Dense Breast[J]. CT Theory and Applications, 2020, 29(1): 79-88. DOI: 10.15953/j.1004-4140.2020.29.01.10
Citation: MIAO Na, QI Xuhong, DU Changyue, CHEN Shiguang, BI Dongmei, WEN Zhiyong. The Application Value of Chest Multi-slice Spiral CT in the Diagnosis of Mass in Dense Breast[J]. CT Theory and Applications, 2020, 29(1): 79-88. DOI: 10.15953/j.1004-4140.2020.29.01.10

胸部MSCT在致密型乳腺肿块诊断中的应用价值

The Application Value of Chest Multi-slice Spiral CT in the Diagnosis of Mass in Dense Breast

  • 摘要: 目的:探讨胸部多层螺旋CT(MSCT)对乳腺肿块的诊断价值。方法:收集经手术病理证实的72例乳腺肿块患者的术前胸部MSCT及乳腺X线摄影的影像学资料,包括乳腺恶性肿块54例,良性肿块18例。根据患者乳腺腺体类型分为非致密型组(23例)、致密型组(49例)。以病理检查结果为参考,评价胸部MSCT检查及乳腺X线摄影对不同腺体类型乳腺肿块的诊断效能。结果:致密型乳腺组,胸部MSCT对恶性肿块诊断准确率为89.19%,高于乳腺X线摄影的67.57%,差异有统计学意义(P=0.024,χ2=5.103);胸部MSCT对良性肿块诊断准确率为75%,高于乳腺X线摄影的58.33%。非致密型乳腺组,乳腺X线摄影对恶性肿块诊断准确率94.12%,略高于胸部MSCT 82.35%。胸部MSCT、乳腺X线摄影对全部乳腺肿块诊断准确率分别为86.11%和75%。胸部MSCT对转移性淋巴结及胸部转移灶的检出率优于乳腺X线摄影。结论:胸部MSCT对乳腺肿块的定性诊断具有较高价值。胸部MSCT对致密型乳腺中肿块的诊断较乳腺X线摄影可提供更多信息、提高诊断准确率。

     

    Abstract: Objective:To evaluate the diagnostic value of chest multi-slice spiral CT in breast mass. Methods:Imaging data of preoperative chest MSCT and mammography in 72 patients with breast masses confirmed by surgical pathology were collected. There were 54 cases of malignant breast mass and 18 cases of benign breast mass. Patients were divided into non-dense group (23 cases) and dense group (49 cases) according to the types of breast glands. Taking pathological examination results as reference, the diagnostic efficiency of breast masses in chest MSCT and mammography was evaluated. Results:In the dense breast group, the diagnostic accuracy of chest MSCT for malignant mass was 89.19%, higher than that of mammography 67.57%, and the difference was statistically significant (P=0.024, χ2=5.103); the diagnostic accuracy of chest MSCT for benign mass was 75% higher than that of mammography 58.33%. In the non-dense breast group, the diagnostic accuracy of mammography for malignant mass was 94.12%, slightly higher than chest MSCT of 82.35%. The diagnostic accuracy of chest MSCT and mammography for all breast masses was 86.11% and 75%. The detection rate of chest MSCT for metastatic lymph nodes and chest metastases was better than that of mammography. Conclusion:Breast MSCT has high value in qualitative diagnosis of breast mass. Chest MSCT can provide more information and improve the diagnostic accuracy of dense breast mass than mammography.

     

/

返回文章
返回