ISSN 1004-4140
CN 11-3017/P
邓茂松, 张淑慧, 王旭, 吴戈, 尹晓明, 李宝平, 曲银娥. 宝石CT低剂量双相扫描测定肺体积在煤工尘肺患者中的应用研究[J]. CT理论与应用研究, 2016, 25(6): 695-701. DOI: 10.15953/j.1004-4140.2016.25.06.10
引用本文: 邓茂松, 张淑慧, 王旭, 吴戈, 尹晓明, 李宝平, 曲银娥. 宝石CT低剂量双相扫描测定肺体积在煤工尘肺患者中的应用研究[J]. CT理论与应用研究, 2016, 25(6): 695-701. DOI: 10.15953/j.1004-4140.2016.25.06.10
DENG Mao-song, ZHANG Shu-hui, WANG Xu, WU Ge, YIN Xiao-ming, LI Bao-ping, QU Yin-e. The Application of Lung Volume Measurement with Gemstone HDCT Low-dose Dual Phase Scanning in Patients with Coal Workers Pneumoconiosis[J]. CT Theory and Applications, 2016, 25(6): 695-701. DOI: 10.15953/j.1004-4140.2016.25.06.10
Citation: DENG Mao-song, ZHANG Shu-hui, WANG Xu, WU Ge, YIN Xiao-ming, LI Bao-ping, QU Yin-e. The Application of Lung Volume Measurement with Gemstone HDCT Low-dose Dual Phase Scanning in Patients with Coal Workers Pneumoconiosis[J]. CT Theory and Applications, 2016, 25(6): 695-701. DOI: 10.15953/j.1004-4140.2016.25.06.10

宝石CT低剂量双相扫描测定肺体积在煤工尘肺患者中的应用研究

The Application of Lung Volume Measurement with Gemstone HDCT Low-dose Dual Phase Scanning in Patients with Coal Workers Pneumoconiosis

  • 摘要: 目的:探讨宝石CT低剂量双期扫描测定肺体积在煤工尘肺患者中的应用价值。方法:选择30例煤工尘肺男性患者行吸气相与呼气相双期低剂量宝石探测器64排HDCT胸部检查,图像重建采用适应性统计迭代重建(ASIR)技术,并在CT检查后3日内完成肺功能检查(PFT)。从既往行常规剂量64排VCT胸部检查的男性患者中选取30例做为对照组。得出各组图像的噪声和每次扫描的容积CT剂量指数(CTDI,DLP,ED)。两组间图像质量主观评分比较采用非参数Mann-Whitney U检验。以配对样本t检验比较两组间不同扫描剂量及不同呼吸状态下的图像噪声、容积CT剂量指数。采用Pearson相关分析检验全肺各容积指标(Vin,Vex,Vin–Vex,Vex/Vin,Vin–Vex/Vin 100%)与PFT指标(FVC,FEV1,FEV1/FVC%)的相关性。结果:所有图像质量主观评价均在中等评级以上,两组扫描的图像噪声无统计学意义;HDCT低剂量扫描并采用ASIR技术双相扫描剂量之和低于VCT常规剂量单次扫描剂量。煤工尘肺患者的肺容积指标(Vin,Vex,Vex/Vin,Vin–Vex/Vin100%)与PFT指标(FVC,FEV1%,FEV1/FVC%)三者均有比较好的相关性,其中Vex、Vex/Vin与PFT指标的相关性更好(P值均<0.01)。结论:宝石CT低剂量双相扫描肺体积指标可用于评价煤工尘肺患者肺功能,临床应用价值较高。

     

    Abstract: Objective: To investigate the application value of HDCT low-dose dual phase scanning measurement of lung volume in patients with coal workers pneumoconiosis. Methods: Totally 30 cases of male patients with coal workers pneumoconiosis underwent low-dose chest examination with HDCT at inspiratory and expiratory phase, image reconstruction using adaptive statistical iterative reconstruction(ASIR), and all patients underwent pulmonary function tests(PFT) within 3 days after the CT scanning. The control group from the usual male patients who underwent routine dose with 64 rows of VCT chest scanning about 30 cases. Each the noise of the image and each scan volume CT dose index(CTDI, DLP, ED) was converted. The subjective image quality score between the two groups to compare the nonparametric Mann-Whitney U test. With paired samples t test to compare different scan dose and breathing state between the two groups of image noise, the volumetric CT dose index. The Pearson correlation analysis inspection throughout the lung volume index(Vin, Vex, Vin-Vex, Vex/Vin, Vin-Vex/Vin100%) and PFT index(FVC, FEV1, FEV1/FVC%). Results: All the subjective image quality evaluation in middle rating above, the image noise between two groups of the scanned without statistical significance; The sam of radiation dose of low-dose scan using ASIR technology dual phase scanning with HDCT lower than the routine dose in a single scan with VCT. Correlation was found between the lung volume index(Vin, Vex, Vex/Vin, Vin-Vex/Vin 100%) and PFT index(FVC, FEV1, FEV1/FVC%) in Coal workers pneumoconiosis patients. The Vex, Vex/Vin had a better correlation with PFT index(P<0.01). Conclusion: HDCT low-dose dual phase scanning of lung volume index can be used for assessment of lung function in patients with coal workers pneumoconiosis, and its clinical application value is high.

     

/

返回文章
返回