  • 摘要: 目的:研究CT导向胸部病灶穿刺活检的方法及应用价值。材料与方法:83例中,肺内病变70例,纵隔病变10例,胸壁及胸膜病变3例,穿刺针为肺活检针,共穿93针。结果:穿刺成功率为100%,取材病理检验效果,理想占80.7%,可靠占13.3%,总可靠率为94.0%,不可靠6.0%。结论:精确的定位,熟练的技术及病人的良好配合可提高穿刺成功率和取材的可靠性。

     

    Abstract: purpose: To sum up the experiences of CT-guided percutaneous thoracic puncture biopsy. Materials and Methods: 83 cases mere performed. 70 cases were pulmonary diseases, 10 cases were mediastinal diseases, 3 cases were thoracic wall and pleural diseases. With pulmonary biopsy needle. A total of 93 cuttings were done. Results: The ratio of puncture succession was l00%. The results of cytology and histology: ideal was 80.7%, reliability was l3.3%, the total reliable ratio was 94%, unreliability was 6%. Conclusion: It could be increased the ratio of puncture succession and the reliability of tissue sample that accurate location. skilled operation and the cooperation with the patients.

     

/