ISSN 1004-4140
CN 11-3017/P

非小细胞肺癌DLSCT双期定量参数与Ki-67表达水平的相关性研究

高楠琳, 王新文, 薛莉雅, 王杰, 丁金祥

高楠琳, 王新文, 薛莉雅, 等. 非小细胞肺癌DLSCT双期定量参数与Ki-67表达水平的相关性研究[J]. CT理论与应用研究(中英文), xxxx, x(x): 1-8. DOI: 10.15953/j.ctta.2024.299.
引用本文: 高楠琳, 王新文, 薛莉雅, 等. 非小细胞肺癌DLSCT双期定量参数与Ki-67表达水平的相关性研究[J]. CT理论与应用研究(中英文), xxxx, x(x): 1-8. DOI: 10.15953/j.ctta.2024.299.
GAO N L, WANG X W, XUE L Y, et al. Correlation between Dual-Phase Quantitative Parameters from Dual-Layer Spectral Detector Computed Tomography and Ki-67 Expression in Non-Small Cell Lung Cancer[J]. CT Theory and Applications, xxxx, x(x): 1-8. DOI: 10.15953/j.ctta.2024.299. (in Chinese).
Citation: GAO N L, WANG X W, XUE L Y, et al. Correlation between Dual-Phase Quantitative Parameters from Dual-Layer Spectral Detector Computed Tomography and Ki-67 Expression in Non-Small Cell Lung Cancer[J]. CT Theory and Applications, xxxx, x(x): 1-8. DOI: 10.15953/j.ctta.2024.299. (in Chinese).

非小细胞肺癌DLSCT双期定量参数与Ki-67表达水平的相关性研究

详细信息
    作者简介:

    高楠琳,女,山西医科大学在读硕士,主要研究方向为胸部系统疾病诊断

    通讯作者:

    王新文✉,男,山西医科大学第二医院放射科主任医师,主要从事胸部系统疾病影像诊断及研究,E-mail:sxeywxw@163.com

Correlation between Dual-Phase Quantitative Parameters from Dual-Layer Spectral Detector Computed Tomography and Ki-67 Expression in Non-Small Cell Lung Cancer

  • 摘要:

    目的:研究双层探测器光谱CT(DLSCT)双期定量参数对非小细胞肺癌Ki-67表达的预测价值。方法:回顾性分析我院自2022年8月至2024年12月进行DLSCT双期增强扫描且经病理证实的非小细胞肺癌患者77例,按免疫组化结果分为低表达组(Ki-67≤30%)、高表达组(Ki-67>30%)。使用Spectral CT viewer软件测量、计算、分析两组病例动脉期和静脉期的双层光谱CT定量参数,包括碘密度(IC)、标准化碘密度(NIC)、有效原子序数(Zeff)、能谱曲线斜率(K40-100 keV,简称K)、MonoE(单能量光谱结果)间隔10 keV的CT40 keV-CT100 keV。统计学方法:采用独立样本t检验方法比较组间差异;用Spearman相关分析评价DLSCT双期定量参数和Ki-67表达水平间的相关性;绘制受试者工作曲线(ROC),获得曲线下面积(AUC),约登指数、敏感度、特异度衡量DLSCT各定量参数评估Ki-67表达水平的效能。结果:静脉期低表达组IC、NIC、Zeff、K40-100 keV、CT40 keV-CT70 keV(间隔10 keV)均高于高表达组,动脉期低表达组K40-100 keV、CT40 keV高于高表达组,差异均具有统计学意义。静脉期IC、NIC、Zeff、K40-100 keV、CT40 keV-CT60 keV(间隔10 keV)、动脉期K40-100 keV、CT40 keV与Ki-67表达水平呈负相关。绘制ROC,静脉期K40-100 keV评估非小细胞肺癌Ki-67表达水平最佳。结论:DLSCT双期定量参数是预测非小细胞肺癌 Ki-67 表达水平的有效工具,研究证据表明静脉期能谱曲线斜率 (K) 是其中最具预测价值的指标。

    Abstract:

    Objective: We investigated the predictive value of dual-phase quantitative parameters of dual-layer spectral detector computed tomography (DLSCT) combined with Ki-67 expression in non-small-cell lung cancer (NSCLC). Methods: Seventy-seven patients with pathologically confirmed non-small cell lung cancer who underwent dual-phase enhanced scanning at our hospital between August 2022 and December 2024 were retrospectively analyzed. According to immunohistochemical results, they were divided into low (Ki-67≤30%) and high (Ki-67>30%) Ki-67 expression groups. Spectral CT viewer software was used to measure, calculate, and analyze the quantitative parameters obtained with dual-layer spectral CT in the arterial and venous phases in both groups, including iodine density (IC), standardized iodine density (NIC), effective atomic number (Zeff), and energy spectrum curve slope (K, P < 0.05) (referred to as K and MonoE [monochromatic energy spectroscopy]) results, and CT40 keV-CT100 keV at 10 keV intervals. An independent samples t-test was used to compare differences between groups. Spearman’s correlation analysis was used to evaluate the correlation between the quantitative parameters of DLSCT and Ki-67 expression. A receiver-operating characteristic (ROC) curve was constructed to obtain the area under the curve (AUC). Youden index, sensitivity, and specificity were used to measure the efficacy of each quantitative parameter of DLSCT in predicting Ki-67 expression. Results: IC, NIC, Zeff, K40-100 keV, CT40 keV-CT70 keV (interval 10 keV) were higher in the low expression group than in the high expression group in venous phase, and K40-100 keV and CT40 keV were higher in the low expression group than in the high expression group in arterial phase. The differences were statistically significant (P<0.05). IC, NIC, Zeff, K40-100 keV, CT40 keV-CT60 keV (interval 10 keV) in venous phase, and K40-100 keV, CT40 keV in arterial phase correlated negatively with Ki-67 expression level (|r| < 0.40,P < 0.05). The ROC curve showed that K40-100 keV in venous phase was the best parameter for predicting Ki-67 expression in NSCLC (AUC=0.750). Conclusion: Dual-phase quantitative parameters of DLSCT are effective tools for predicting Ki-67 expression in non-small cell lung cancer, and research evidence shows that the slope (K) of the spectral curve in the venous phase is the most valuable index.

  • 双能量CT(dual-energy computed tomography, DECT)作为一种较为先进的成像技术,已广泛应用于临床实践。DECT利用物质在不同X射线能量下的衰减特性,获取高能量和低能量图像数据,从而实现单能量成像、物质成分分离和定量分析[1-3]

    在物质的定量分析中,电子密度(electron density, ED)ρe和有效原子序数(effective atomic number, EAN)Zeff不仅用于结石成分分类和肿瘤良恶性鉴别,还被用于放射治疗的蒙特卡洛剂量估算和放疗后放射性肺炎的分级评估[4-9]。因此,准确测量ρeZeff是实现精准影像诊断和精确剂量估算的基础。虽然已有一些研究探讨了在DECT中测量ρeZeff的准确性,但由于使用的CT机型(双能量成像模式)、扫描和重建参数等存在差异,导致这些研究结果难以进行比较。

    本文综述近年来相关的文献研究,分析影响ρeZeff测量准确性的关键因素,探讨提高这些参数测量精度的方法,旨在提高影像诊断和治疗的精确性。

    常规CT图像的生成是基于不同物质对X射线的衰减程度的差异,这些差异通常用衰减系数μ来量化,并以Hounsfield单位(HU)表示。因此在临床实践中,组织的HU值可能会因光子能量和扫描参数的变化而发生改变。此外,不同的组织也会表现出相同的HU值,这种现象源于衰减系数μ不仅受到光子能量的影响,还与组织密度和元素组成密切相关。1976年,Rutherford 等[10]提出利用不同能量的X射线对同一解剖结构进行至少两次扫描,以获取不同能量下的图像,进而推导出衰减系数μρeZeff之间的关系。

    目前,双能量成像作为主流的能谱CT技术,其X射线能量的解析方法会间接影响ρeZeff的计算结果。能量解析主要有两种方法:基于投影数据域的解析和基于图像域的解析[11]。前者通过减少射线束硬化效应,提高了解析的准确性,但计算过程更为复杂且对噪声更加敏感;后者则在计算简便性和对噪声的抗干扰能力上具有优势[12]。总之,射线束硬化效应和噪声都可能对物质的衰减系数μ造成干扰,进而影响对组织ρeZeff的测量精度。

    CT系统采用多色能谱X射线技术,在X射线穿透介质的过程中,大量低能X射线被吸收衰减,而高能X射线的衰减相对较少,导致透射线束中的高能X射线比例提高,出现“射线束硬化”的现象[13]。在这过程中,衰减系数μ发生了变化。然而,在图像重建过程中,通常假设X射线能谱为单色,即认为衰减系数μ是恒定不变的。这种假设会导致实际的衰减系数μ与假定值之间出现偏差,进而影响到ρeZeff的测量精度。

    随着被测物体体积的增大,射线束硬化效应变得更加显著,这将导致ρeZeff的测量误差进一步增大。Schaeffer等[14]在研究中指出,在较小尺寸的头部模型中,ρeZeff的测量值比在较大尺寸的体部模型中更为精确。然而,Almeida等[15]的研究结果与之不同,在两种不同尺寸的模型中,ρeZeff的测量值并无显著差异,这可能源于事先使用模体进行了ρeZeff的校准,有效地校正了射线束硬化效应。值得注意的是,尽管Hua等[16]没有使用模体进行校准,但他们的研究结果与Almeida等[15]相似,发现两种尺寸模型中ρeZeff的测量值差异控制在0.7% 和2% 以内。这可能与他们使用的双层探测器CT技术有关,该技术能够实现基于投影数据的材料分解,有效减轻射线束硬化的影响。

    除体型尺寸外,扫描中心的偏移也是影响射线束硬化效应的一个重要因素。Schaeffer等[14]发现,当模体在上下左右4个方向上发生偏移时,Zeff会有 3% 的变化,而ρe则相对不敏感。尽管Zeff的变化幅度不大,但这足以对物质的鉴别造成影响。例如,在偏离等中心点的模体中,血液等效组织插件(40 HU)的Zeff与未发生偏移模体中的水等效组织插件的Zeff相近。由于扫描位置受到受检者特异性及摆位技师判断偏倚的影响,难以通过其他方法进行校正,因此,制定标准化的摆位流程对于提高ρeZeff测量的准确性至关重要。

    噪声具有随机性、不确定性,会干扰正常信号的接收与处理。在CT成像领域,噪声的存在不仅影响图像的纹理,还会导致衰减系数μ的测量值与其真实值之间存在偏差。在临床实践中,降低噪声对于提升CT图像质量至关重要。为了减少噪声对衰减系数μ测量的影响,提高ρeZeff的测量精度,选择恰当的扫描参数和应用高效的噪声抑制技术显得尤为关键。

    CT噪声主要与探测器接收的X射线光子量有关,增加X射线能量或扫描剂量可以降低噪声水平。Landry等[17]的研究表明,随着曝光剂量的增加,模体中脂肪、水、肌肉等效组织插件的ρeZeff的区分度提高,同时在近距离放疗的蒙特卡洛模拟中,剂量计算的误差也相应减小。然而,Hua等[16]的研究发现,在不同的管电压和剂量水平下,ρeZeff的测量展现出较高的准确性和稳定性。这一结果可能与Hua等[16]使用的曝光剂量范围较窄,而Landry等[17]则采用了0.5至4倍的剂量范围有关。

    除了剂量和能量外,迭代算法也是影响CT噪声的关键因素。与传统的滤波反投影(filtered back projection,FBP)算法相比,迭代重建算法有效地降低了图像噪声并提高了图像质量[18-20]。Landry等[17]发现正弦图确定迭代重建(sinogram-affirmed iterative reconstruction,SAFIRE)算法在降低ρeZeff的标准偏差方面表现优于FBP算法,尤其在使用最大强度时。也有其他研究指出,ρeZeff的测量精度与迭代重建算法的强度并无明显关联[16,21],这可能与不同研究中使用的CT机品牌和型号有关。

    除了上述参数,层厚、螺距、旋转时间、卷积核等其他扫描参数同样对CT噪声有着显著影响,这些因素对ρeZeff测量准确性的影响值得进一步研究和探讨。

    根据不同的双能量实现方式,DECT可分为单源瞬时管电压切换模式、单源序列扫描模式、双源双能量扫描模式、单源双光束模式和单源双层探测器模式[22]图1)。DECT通过获取物质在两种不同能量下的X射线衰减信息,利用物质在不同能量下的衰减差异进行物质分解和定量分析(图2图3)。

    图  1  双能量CT的不同成像模式
    Figure  1.  Different imaging modes of dual-energy CT
    图  2  电子密度和有效原子序数的计算原理[23]
    Figure  2.  Calculation principles of electron density and effective atomic number[23]
    图  3  电子密度和有效原子序数在胆脂瘤患者中的应用
    注:女,61岁,胆脂瘤伴肉芽肿。
    Figure  3.  Application of electron density and effective atomic number in patients with cholesteatoma.

    (1)单源瞬时管电压切换模式DECT可在机架旋转期间实现高低电压的快速切换,尽管X射线投影角度几乎相同,允许基于投影数据域进行能量解析,但由于时间分辨力的损失,会在一定程度上影响能量解析的准确性。

    当前的研究在评估Zeff测量的准确性方面展现了不同结果[21,24,25]。例如,Goodsitt等[24]通过模体实验得出Zeff的测量相对误差控制在15% 以内的结论。相对地,Kawahara等[25]报告称Zeff的测量相对误差在5.1% 以内。这种差异可能是因为各研究中所采用的CT机型和扫描参数不同,以及模体材料和结构的多样性所致。在ρe测量的准确性方面,Ogata等[26]发现在不同单能级图像中,模体所有材料的ρe测量相对误差控制在1.1% 以内。目前,基于单源瞬时管电压切换模式的DECT测量ρe准确性的研究相对较少,未来可进一步探索。

    (2)单源序列扫描模式DECT分别以高、低能量进行两次扫描实现双能量成像。两套独立的高低能量图像具有完全的能量分离效果,这种特性有助于提高ρeZeff的测量准确性。当前,相关研究表明ρeZeff的测定具有较高的精度,有助于提高放射治疗计划的准确性[14,27-29]。其中Schaeffer等[14]基于模体实验发现Zeff的测量相对误差为3.2%,并且认为与Kawahara等[25]基于单源瞬时管电压切换模式 DECT的研究结果相似(Zeff的测量相对误差为2.5%)。

    在单源序列扫描成像模式下,两次球管旋转扫描之间存在一定的时间(如某品牌CT高低管电压扫描间隔为180~800 ms[28]),可能会影响空间配准效果,并且在临床实践中由于受到受检者运动的影响,导致材料分解存在偏差[30]。此外,较大的能谱分离效果有助于产生更好的材料区分效果,提高ρeZeff的准确性。目前单源序列扫描模式DECT的高能量成像多采用135 kVp的管电压,能谱分离效果略低于单源瞬时管电压切换模式DECT的140 kVp[25]

    (3)双源双能量扫描模式DECT具有较大的能谱分离优势,它采用两套X射线球管和探测器,对同一解剖平面分别发射高、低管电压的X射线并由相应的探测器采集数据。

    随着技术的进步,目前双源DECT多采用能谱纯化技术进一步增大能谱分离效果,减少射线束硬化伪影,提高了ρeZeff的测量准确性[15,31-32]。然而,两套探测器的空间位置设计也会对ρeZeff的测量带来一定的影响,仅35.5 cm的全扫描视野,对于超力型成年受检者的ρeZeff的测量具有局限性。此外,鉴于高、低能量数据采集的相位差异,该双能量CT采用了一种对噪声反应更为敏感的图像域能量解析技术。然而,当两套探测器同时捕获高能和低能X射线时,交叉散射的产生是不可避免的,这种散射会加剧噪声,从而可能对ρeZeff的精确测量带来不利影响。

    (4)单源双光束模式DECT采用分离滤波技术,使X射线束预先分离成高、低能量的两种光子束,由对应位置的探测器沿Z轴方向分别接收,使得同一解剖区域接收高、低能两种X射线束存在时间差异,同样地基于图像域进行能量解析。尽管该模式DECT在成像过程中也容易受到光子交叉、散射等影响,但是相关研究发现单源双光束模式DECT在测量ρeZeff的准确性方面劣于双源DECT[15]。该研究发现第2代、第3代双源DECT的ρeZeff的测量相对误差分别在1.2% 和6.2% 以内,然而单源双光束DECT的ρeZeff的测量相对误差最大可达15.3% 和28.1%。较大的测量误差可能源于单源双光束DECT的高能和低能数据均源自相同的管电压设置,这种设计导致能谱分离效果相对较弱,从而使得成像系统对图像噪声和伪影更为敏感,影响了ρeZeff的准确性。

    (5)单源双层探测器模式DECT同样对高能和低能数据采用了相同的管电压设置,并且存在使用相同管电流所致的高、低能光谱图像的噪声水平不同的局限,但相关研究显示出了稳健的ρeZeff的测量准确性[16,33]

    Hua等[16]基于模体实验发现ρe的测量相对误差范围在 -0.1% 至1.1%,Zeff的测量相对误差范围为 -2.3% 至1.7%。这些发现可以归因于该模式的DECT采用了独特的设计:一个X射线球管与空间上对称分布的上下两层探测器相结合。这种双层探测器配置能够同步捕获高、低能量的X射线信息,实现了基于投影数据域的材料分解[34]。从理论上讲,这种方法相较于基于图像域的材料分解具有一定的优势。

    DECT根据不同能量下物质衰减系数μ的差异进行物质分解,以实现单能量CT扫描无法评估的物质特性,其中ρeZeff在评估材料特性和放疗剂量估算中发挥着重要的作用。本文重点探讨影响ρeZeff测量精度的射线束硬化效应和噪声两大关键因素,并详细分析不同双能量成像模式CT对ρeZeff测量准确性的具体影响,明确了各成像模式的优势与局限。

    鉴于此,未来的研究需进一步探索和优化算法,以减轻射线束硬化效应和噪声的不利影响,从而提升图像质量和测量的精确度。同时,由于不同双能量成像模式CT对ρeZeff测量准确性的差异化影响,未来的工作还需对这些成像模式进行细致的比较研究,并针对不同双能量成像模式CT,探索所使用机型的最佳成像条件以提高ρeZeff的测量准确性。

  • 图  1   患者女,55岁,右肺下叶腺癌(圆圈为ROI),Ki-67为3%

    注:(a)~(d)依次为有效原子序数图(Zeff=8.13)、碘密度图(IC=1.54)、胸部40 keV单能量图(CT40 keV=184.446)、能谱曲线图(K=1.94)。

    Figure  1.   A 55-year-old female patient with adenocarcinoma of the right lower lobe of the lung (circle is ROI), Ki-67 was 3%

    图  2   患者女,66岁,右肺上叶鳞癌(圆圈为ROI),Ki-67为60%

    注:(a)~(d)依次为有效原子序数图(Zeff=7.94)、碘密度图(IC=1.12)、胸部40 keV单能量图(CT40 keV=133.940)、能谱曲线图(K=1.36)。

    Figure  2.   A 66-year-old female patient with squamous cell carcinoma in the right upper lobe of the lung (circle is ROI), Ki-67 was 60%

    图  3   静脉期光谱CT各参数鉴别Ki-67高表达组与非高表达组的ROC曲线

    Figure  3.   ROC curve of each parameter of venous phase spectral CT for identifying high and low Ki-67 expression groups

    图  4   动脉期光谱各参数鉴别Ki-67高表达组与非高表达组的ROC曲线

    Figure  4.   The receiver operating characteristic (ROC) curve of each parameter of arterial phase spectral CT in identifying high and low Ki-67 expression groups

    表  1   Ki-67高、低表达组静脉期光谱CT各参数比较

    Table  1   Comparison of spectral CT parameters in venous phase from high and low Ki-67 expression groups

    参数组别统计检验
    低表达组高表达组t值P值
    n2750
    IC/(mg/mL)1.37±0.391.12±0.362.90.01
    NIC0.31±0.080.25±0.083.27<0.01
    Zeff8.08±0.187.95±0.262.30.02
    K40-100 keV1.87±0.441.43±0.483.93<0.01
    CT40 keV/HU164.68±32.27137.72±34.983.31<0.01
    CT50keV/HU121.38±26.42103.3±25.392.94<0.01
    CT60 keV/HU93.03±17.3781.84±17.872.650.01
    CT70 keV/HU75.8±13.6268.37±13.142.340.02
    CT80 keV/HU63.86±12.7660.71±11.531.10.28
    CT90 keV/HU56.6±12.9255.38±9.960.460.65
    CT100 keV/HU52.68±11.9751.78±9.020.370.71
    下载: 导出CSV

    表  2   Ki-67高、低表达组动脉期光谱CT各参数比较

    Table  2   Comparison of arterial phase spectral CT parameters from high and low Ki-67 expression groups

    参数 组别 统计检验
    低表达组 高表达组 t值 P值
    n 27 50
    IC/(mg/mL) 1.31±0.39 1.15±0.36 1.5 0.14
    NIC 0.11±0.03 0.09±0.04 1.75 0.08
    Zeff 7.99±0.24 7.95±0.26 0.66 0.51
    K40-100 keV 1.61±0.45 1.33±0.50 2.42 0.02
    CT40 keV/HU 150.30±31.75 132.03±35.03 2.26 0.03
    CT50keV/HU 109.08±21.23 100.58±24.32 1.53 0.13
    CT60 keV/HU 86.11±15.43 80.42±16.98 1.45 0.15
    CT70 keV/HU 72.69±12.37 68.32±12.50 1.47 0.15
    CT80 keV/HU 63.54±10.60 60.60±9.96 1.21 0.23
    CT90 keV/HU 57.66±9.72 55.51±8.26 1.03 0.31
    CT100 keV/HU 53.54±9.23 52.01±7.19 0.81 0.42
    下载: 导出CSV

    表  3   静脉期光谱CT各参数与Ki-67表达水平的相关性分析

    Table  3   Correlation analysis between Ki-67 expression and parameters from venous phase spectral CT

    r值P值
    分组1
    IC(mg/ml)−0.2670.02
    NIC−0.2970.01
    Zeff−0.2510.03
    K40-100 keV−0.398<0.01
    CT40 keV(HU)−0.3150.01
    CT50keV(HU)−0.2780.01
    CT60 keV(HU)−0.2430.03
    CT70 keV(HU)−0.1940.10
    CT80 keV(HU)−0.0620.60
    CT90 keV(HU)−0.007−0.95
    CT100 keV(HU)−0.0070.95
    下载: 导出CSV

    表  4   动脉期光谱CT各参数与Ki-67表达水平的相关性分析

    Table  4   Correlation analysis between Ki-67 expression and parameters from arterial phase spectral CT

    分组 K40-100 keV CT40 keV(HU)
    r值1−0.225−0.225
    P值0.05<0.05
    下载: 导出CSV

    表  5   光谱CT各参数诊断Ki-67高表达组与非高表达组肺癌病灶的效能

    Table  5   Efficacy of spectral CT parameters in diagnosis of lung cancer lesions in the high Ki-67 group and the low Ki-67 group

    指标 约登指数 临界值 敏感度(%) 特异度(%) AUC 95%CI
    IC (V)0.2841.14570.458.00.6740.549-0.799
    NIC(V)0.2750.24581.546.00.6830.561-0.804
    Zeff(V)0.2927.92585.244.00.6600.538-0.782
    K40-100 keV(V)0.4091.36688.952.00.7500.641-0.859
    CT40 keV(V)0.347150.77266.768.00.6980.575-0.820
    CT50 keV(V)0.356116.92155.680.00.6790.549-0.809
    CT60 keV(V)0.35389.04759.376.00.6660.536-0.796
    CT70 keV(V)0.31674.61055.676.00.6440.513-0.776
    K40-100 keV(A)0.3211.40774.158.00.6620.537-0.788
    CT40 keV(A)0.295130.26481.548.00.6570.531-0.783
    注:AUC:曲线下面积;CT40 keV(V)、CT40 keV(A):分别代表静脉期CT40 keV、动脉期CT40 keV,余数据以此类推。
    下载: 导出CSV
  • [1]

    KIRI S, RYBA T. Cancer, metastasis, and the epigenome[J]. Molecular Cancer, 2024, 23(1): 154. DOI: 10.1186/s12943-024-02069-w.

    [2]

    SIEGEL R L, GIAQUINTO A N, JEMAL A. Cancer statistics, 2024[J]. CA: a cancer journal for clinicians, 2024, 74(1). DOI: 10.3322/caac.21820

    [3]

    LEITER A, VELUSWAMY R R, WISNIVESKY J P. The global burden of lung cancer: current status and future trends[J]. Nature reviews Clinical oncology, 2023, 20(9): 624-639. DOI: 10.1038/s41571-023-00798-3.

    [4]

    MROUJ K, ANDRéS-SáNCHEZ N, DUBRA G, et al. Ki-67 regulates global gene expression and promotes sequential stages of carcinogenesis[J]. Proceedings of the National Academy of Sciences, 2021, 118(10): e2026507118. DOI: 10.1073/pnas.2026507118.

    [5]

    LUO X, ZHENG R, ZHANG J, et al. CT-based radiomics for predicting Ki-67 expression in lung cancer: a systematic review and meta-analysis[J]. Frontiers in Oncology, 2024, 14: 1329801. DOI: 10.3389/fonc.2024.1329801.

    [6]

    DENG L, YANG J, ZHANG M, et al. Whole-lesion iodine map histogram analysis versus single-slice spectral CT parameters for determining novel International Association for the Study of Lung Cancer grade of invasive non-mucinous pulmonary adenocarcinomas[J]. Diagnostic and Interventional Imaging, 2024, 105(5): 165-173. DOI: 10.1016/j.diii.2023.12.001.

    [7]

    MA Y, LI S, HUANG G, et al. Role of iodine density value on dual-energy CT for detection of high tumor cell proportion region in lung cancer during CT-guided transthoracic biopsy[J]. European Journal of Radiology, 2023, 160: 110689. DOI: 10.1016/j.ejrad.2023.110689.

    [8]

    LIN L, CHENG J, TANG D, et al. The associations among quantitative spectral CT parameters, Ki-67 expression levels and EGFR mutation status in NSCLC.[J]. Sci Rep, 2020, 1: 3436. DOI: 10.1038/s41598-020-60445-0.

    [9]

    ZHU T, XIE K, WANG C, et al. Diagnostic Effectiveness of Dual Source Dual Energy Computed Tomography for Benign and Malignant Thyroid Nodules[J]. Evidence‐Based Complementary and Alternative Medicine, 2022, 2022(1): 2257304. DOI: 10.1155/2022/2257304.

    [10] 中华放射学杂志双层探测器光谱CT临床应用协作组. 双层探测器光谱CT临床应用中国专家共识(第一版)[J]. 中华放射学杂志, 2020, 54(7): 635-643. DOI: 10.3760/cma.j.cn112149-20200513-00679.

    CHINESE JOURNAL OF RADIOLOGY DUAL-LAYER SPECTRAL DETECTOR CT CLINICAL APPLICATION COLLABORATIVE GROUP. Chinese expert consensus on clinical application of dual-layer spectral detector CT (first edition)[J]. Chinese Journal of Radiology, 2020, 54(7): 635-643. DOI: 10.3760/cma.j.cn112149-20200513-00679.

    [11]

    FULTON N, RAJIAH P. Abdominal applications of a novel detector-based spectral CT[J]. Current Problems in Diagnostic Radiology, 2018, 47(2): 110-118. DOI: 10.1067/j.cpradiol.2017.05.001.

    [12]

    ZHANG Z, ZOU H, YUAN A, et al. A Single Enhanced Dual-Energy CT Scan May Distinguish Lung Squamous Cell Carcinoma From Adenocarcinoma During the Venous phase.[J]. Acad Radiol, 2020, 5: 624-629. DOI: 10.1016/j.acra.2019.07.018.

    [13] 薛莉雅, 赵卫东, 苏琳, 等. 双层探测器光谱CT多参数成像在不同病理类型肺癌中的应用[J]. 中国CT和MRI杂志, 2023, 21(12): 52-55. DOI: 10.3969/j.issn.1672-5131.2023.12.016.

    XUE L Y, ZHAO W D, SU L, et al. Application of multi-parameter imaging of dual-layer spectral detector CT in different pathological types of lung cancer[J]. Chinese journal of CT and MRI, 2023, 21(12): 52-55. DOI: 10.3969/j.issn.1672-5131.2023.12.016.

    [14] 刘秀丽, 张戟风, 刘景旺, 等. 能谱CT在中央型肺癌伴阻塞性肺不张诊断及放疗定位中应用价值[J]. CT理论与应用研究, 2023, 32(4): 509-514. DOI: 10.15953/j.ctta.2022.164.

    LIU X L, ZHANG J F, LIU J W, et al. The value of Spectral CT in differential diagnosis and ra-diotherapy localiation of central lung cancer with obstructive atelectasis[J]. CT Theory and App-lications, 2023, 32(4): 509-514. DOI: 10.15953/j.ctta.2022.164.

    [15]

    WU J, LV Y, WANG N, et al. The value of single-source dual-energy CT imaging for discriminating microsatellite instability from microsatellite stability human colorectal cancer.[J]. Eur Radiol, 2019, 7: 3782-3790. DOI: 10.1007/s00330-019-06144-5.

    [16] 田双凤, 杨萌, 夏建国, 等. 实性肺癌能谱CT参数与Ki-67表达水平的相关性研究[J]. 影像诊断与介入放射学, 2021, 30(1): 20-24. DOI: 10.3969/j.issn.1005-8001.2021.01.004.

    TIAN S F, YANG M, XIA J G, et al. Correlation between spectral CT parameters and Ki-67 expression in solid lung cancer [J]. The imaging diagnosis and interventional radiology, 2021, 30 (1) : 20 to 24. DOI: 10.3969 / j.i SSN. 1005-8001.2021.01.004.

    [17] 周潋滟, 张浩荡, 殷世武. 双层光谱CT评估非小细胞肺癌Ki-67表达水平的可行性[J]. 中国介入影像与治疗学, 2023, 20(2): 107-111. DOI: 10.13929/j.issn.1672-8475.2023.02.011.

    ZHOU L Y, ZHANG H D, YIN S W. Feasibility of assessing Ki-67 expression level in non-small cell lung cancer using dual-layer spectral CT[J]. Chinese interventional imaging and therapy, 2023, 20(2): 107-111. DOI: 10.13929/j.issn.1672-8475.2023.02.011.

    [18]

    MAO L T, CHEN W C, LU J Y, et al. Quantitative parameters in novel spectral computed tomography: Assessment of Ki-67 expression in patients with gastric adenocarcinoma[J]. World Journal of Gastroenterology, 2023, 29(10): 1602. DOI: 10.3748/wjg.v29.i10.1602.

    [19]

    ZEGADŁO A, ŻABICKA M, RóŻYK A, et al. A new outlook on the ability to accumulate an iodine contrast agent in solid lung tumors based on virtual monochromatic images in dual energy computed tomography (DECT): Analysis in two phases of contrast enhancement[J]. Journal of Clinical Medicine, 2021, 10(9): 1870. DOI: 10.3390/jcm10091870.

    [20]

    WU Y, LI J, DING L, et al. Differentiation of pathological subtypes and Ki-67 and TTF-1 expression by dual-energy CT (DECT) volumetric quantitative analysis in non-small cell lung cancer[J]. Cancer Imaging, 2024, 24(1): 146. DOI: 10.1186/s40644-024-00793-6.

    [21]

    DOU P, LIU Z, XIE L, et al. The predictive value of energy spectral CT parameters for assessing Ki-67 expression of lung cancer[J]. Translational Cancer Research, 2020, 9(7): 4267. DOI: 10.21037/tcr-19-2769a.

    [22] 窦沛沛, 赵恒亮, 曹爱红. 能谱CT联合肿瘤标志物预测肺腺癌Ki-67表达[J]. CT理论与应用研究, 2023, 32(6): 753-760. DOI: 10.15953/j.ctta.2022.172.

    DOU P P, ZHAO H L, CAO A H. Spectral CT combined with tumor markers to predict Ki-67 expression in lung adenocarcinoma[J]. CT Theory and Applications, 2023, 32(6): 753-760. DOI: 10.15953 / j.carol carroll tta. 2022.172. DOI: 10.15953/j.ctta.2022.172.

    [23]

    YU J, LIN S, LU H, et al. Optimize scan timing in abdominal multiphase CT: Bolus tracking with an individualized post-trigger delay. [J]. Eur J Radiol, 2022: 110139. DOI: 10.1016/j.ejrad.2021.110139

    [24]

    QI K, LI L, YUAN D, et al. Optimized contrast enhancement and homogeneity in aortic CT angiography: bolus tracking with personalized post-trigger delay[J]. Quantitative Imaging in Medicine and Surgery, 2024, 15(1): 709. DOI: 10.21037/qims-24-624.

    [25]

    YUAN D, LI L, ZHANG Y, et al. Image quality improvement in head and neck CT angiography: Individualized post-trigger delay versus fixed delay. [J]. Eur J Radiol, 2023, 111142. DOI: 10.1016/j.ejrad.2023.111142

图(4)  /  表(5)
计量
  • 文章访问数:  3
  • HTML全文浏览量:  1
  • PDF下载量:  3
  • 被引次数: 0
出版历程
  • 收稿日期:  2024-12-11
  • 修回日期:  2025-02-27
  • 录用日期:  2025-02-27
  • 网络出版日期:  2025-04-05

目录

/

返回文章
返回
x 关闭 永久关闭