北京市大兴区人民医院成年人CT检查辐射剂量及其典型值调查与分析

Investigation and Analysis of Radiation Dose and Typical Values in Adult Computed Tomography Examinations

  • 摘要: 目的:调查本单位各台CT设备的辐射剂量水平和典型值,为提升辐射风险防范最优化提供依据。方法:回顾性分析我院2023年7~12月5台CT设备头颅、胸部、腹部检查的扫描参数及辐射剂量数据,确定其典型值(中位数),并与国内外的DRL进行比较。结果:本次调查头颅、胸部、腹部的容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)典型值分别为54.40 mGy,735.80 mGy·cm;14.20 mGy,443.60 mGy·cm;16.40 mGy,678.20 mGy·cm。头颅的CTDIvol、DLP典型值最高,腹部次之,胸部最低。头颅CTDIvol及DLP存在随年龄增加而略增大趋势。不同使用年限CT设备的头颅、腹部CTDIvol、DLP存在显著性统计学差异(P<0.01)。本次调查各部位DLP较其他国家偏低。除了头颅DLP稍偏大,其余辐射剂量均低于国家卫生行业标准。腹部DLP较其它省市偏大。结论:本次调查成人CT辐射剂量与国内外结果基本一致,需要对CT检查的扫描范围进行规范化培训和优化,以减少受检者不必要的辐射暴露。

     

    Abstract: Objective: This study aimed to investigate the radiation dose levels and typical values of computed tomography (CT) devices in our unit, providing a basis for optimizing radiation protection. Methods: The scanning parameters and radiation dose data of head, chest, and abdominal examinations from five CT devices in our hospital from July to December 2023 were retrospectively analyzed. Median values were determined and compared with domestic and international diagnostic reference levels (DRL). Results: The typical values for the volume CT dose index (CTDIvol) and dose length product (DLP) were 54.40 mGy and 735.80 mGy·cm, 14.20 mGy and 443.60 mGy·cm, and 16.40 mGy and 678.20 mGy·cm for head, chest, and abdomen, respsectively. The highest CTDIvol and DLP typical values were observed in head examinations, followed by abdominal and chest. CTDIvol and DLP for head examinations slightly increased with age. Significant statistical differences (P < 0.01) were found in CTDIvol and DLP for head and abdominal CT examinations with different years of use. Here, the DLP values were lower than those in other countries. Excluding a slightly higher head DLP, all other radiation doses were below the national health industry standards. Abdominal DLP was higher than other provinces and cities. Conclusion: Radiation doses of adult CT examinations in this survey are consistent with domestic and international results. Standardized training and optimization of the scanning range in CT examinations are needed to reduce unnecessary radiation exposure to patients.

     

/