ISSN 1004-4140
CN 11-3017/P

基于参考组分的双能CT成像方法

王文杰, 陈平, 潘晋孝, 李毅红

王文杰, 陈平, 潘晋孝, 李毅红. 基于参考组分的双能CT成像方法[J]. CT理论与应用研究, 2021, 30(1): 61-69. DOI: 10.15953/j.1004-4140.2021.30.01.06
引用本文: 王文杰, 陈平, 潘晋孝, 李毅红. 基于参考组分的双能CT成像方法[J]. CT理论与应用研究, 2021, 30(1): 61-69. DOI: 10.15953/j.1004-4140.2021.30.01.06
WANG Wenjie, CHEN Ping, PAN Jinxiao, LI Yihong. Dual-energy CT Imaging Method Based on Reference Components[J]. CT Theory and Applications, 2021, 30(1): 61-69. DOI: 10.15953/j.1004-4140.2021.30.01.06
Citation: WANG Wenjie, CHEN Ping, PAN Jinxiao, LI Yihong. Dual-energy CT Imaging Method Based on Reference Components[J]. CT Theory and Applications, 2021, 30(1): 61-69. DOI: 10.15953/j.1004-4140.2021.30.01.06

基于参考组分的双能CT成像方法

基金项目: 

国家自然科学基金(61801437;61871351;61971381);山西省自然科学基金(201801D221206;201801D221207);山西省研究生创新项目(2020BY098)。

详细信息
    作者简介:

    王文杰(1996-),男,中北大学硕士研究生,主要从事X射线成像、双能材料分解方面的研究,Tel:18435153867,E-mail:1419261450@qq.com;陈平*(1983-),男,中北大学教授,主要从事X射线成像、光电检测等方面的研究,Tel:13834666067,E-mail:pc0912@163.com。

  • 中图分类号: O434.1;TP301

Dual-energy CT Imaging Method Based on Reference Components

  • 摘要:

    双能CT材料分解对了解物质内部材料分布有重要作用,常规CT所使用的X射线能谱分布未知,无法根据能量信息获得材料衰减系数,并且连续能谱投影与单能重建算法不匹配,导致重建图像衰减系数和材料理论衰减系数之间存在误差,分解结果不准确。针对上述问题,本文引入参考组分获得等效能量信息,进而获得材料的单能衰减系数,并且引入邻域空间欧式距离容差对材料分解模型中的材料组成进行约束,欧氏距离容差根据参考组分重建图像获取。实验结果表明,本文方法能够在常规CT投影系统的基础上,对检测物体中各材料进行准确分解。

    Abstract:

    The material decomposition of dual-energy CT plays an important role in understanding the material distribution inside the substance. The X-ray energy spectrum distribution used in conventional CT is unknown, and the material attenuation coefficient cannot be obtained from the energy information, and the continuous energy spectrum projection does not match the single-energy reconstruction algorithm. There is an error between the attenuation coefficient of the reconstructed image and the theoretical attenuation coefficient of the material, and the decomposition result is not accurate. To solve the above problems, this paper introduces reference components to obtain equivalent energy information, and then obtains the single energy attenuation coefficient of the material, and introduces the Euclidean distance in the neighborhood space the tolerance restricts the material composition in the material decomposition model, and the Euclidean distance tolerance is obtained from the reconstructed image of the reference component. The experimental results show that the method in this paper can accurately decompose the materials in the detected object on the basis of the conventional CT projection system.

  • 期刊类型引用(3)

    1. 张婷婷,钟朝辉,张奥博,程晓悦,王振常. 股前外侧穿支皮瓣术前CT血管成像扫描及重建方案研究. CT理论与应用研究. 2024(06): 661-668 . 本站查看
    2. 项澄,李翠红. 内镜下组织胶三明治夹心法联合钛夹在食管胃底静脉曲张中的应用效果. 中国当代医药. 2024(28): 31-34 . 百度学术
    3. 成娜,雷炜,吴晓华. 对比分析常规增强CT扫描以及能谱CT单能量成像对门静脉血管成像图像质量的影响. 世界复合医学. 2023(12): 83-86 . 百度学术

    其他类型引用(1)

计量
  • 文章访问数:  447
  • HTML全文浏览量:  15
  • PDF下载量:  38
  • 被引次数: 4
出版历程
  • 收稿日期:  2020-11-23
  • 网络出版日期:  2021-11-05

目录

    /

    返回文章
    返回
    x 关闭 永久关闭