ISSN 1004-4140
CN 11-3017/P

能谱CT在急性肺栓塞诊断及肺血流灌注变化评估中的应用

姚标, 李晓峰, 刘彩云, 石岩

姚标, 李晓峰, 刘彩云, 石岩. 能谱CT在急性肺栓塞诊断及肺血流灌注变化评估中的应用[J]. CT理论与应用研究, 2019, 28(6): 693-699. DOI: 10.15953/j.1004-4140.2019.28.06.07
引用本文: 姚标, 李晓峰, 刘彩云, 石岩. 能谱CT在急性肺栓塞诊断及肺血流灌注变化评估中的应用[J]. CT理论与应用研究, 2019, 28(6): 693-699. DOI: 10.15953/j.1004-4140.2019.28.06.07
YAO Biao, LI Xiaofeng, LIU Caiyun, SHI Yan. Application of Energy Spectral CT in the Diagnosis of Acute Pulmonary Embolism and Evaluation of Pulmonary Perfusion Changes[J]. CT Theory and Applications, 2019, 28(6): 693-699. DOI: 10.15953/j.1004-4140.2019.28.06.07
Citation: YAO Biao, LI Xiaofeng, LIU Caiyun, SHI Yan. Application of Energy Spectral CT in the Diagnosis of Acute Pulmonary Embolism and Evaluation of Pulmonary Perfusion Changes[J]. CT Theory and Applications, 2019, 28(6): 693-699. DOI: 10.15953/j.1004-4140.2019.28.06.07

能谱CT在急性肺栓塞诊断及肺血流灌注变化评估中的应用

基金项目: 

江苏大学医学临床科技发展基金(JLY20160071;JLY20180119);徐州市重点研发计划(农业与社会发展)(KC18200)。

详细信息
    作者简介:

    姚标(1985-),男,徐州市肿瘤医院放射科主治医师,主要从事肿瘤与血管性疾病影像诊断与临床技术应用研究,TEL:18796219655,E-mail:yaubiao@126.com;刘彩云*(1981-),女,徐州市肿瘤医院放射科副主任医师,主要从事肿瘤与血管性疾病影像诊断研究,TEL:15205207987,E-mail:liucaiyun7987@163.com。

  • 中图分类号: R812

Application of Energy Spectral CT in the Diagnosis of Acute Pulmonary Embolism and Evaluation of Pulmonary Perfusion Changes

  • 摘要: 目的:探讨能谱CT对急性肺栓塞诊断及肺血流灌注变化评估的应用价值。方法:回顾性分析2017年11月至2019年7月43例怀疑急性肺栓塞的影像资料,所有疑似急性肺栓塞患者行能谱增强扫描,原始数据图像在工作站重建肺动脉血管图像及碘基物质图。观察并记录肺动脉栓子的位置、数目;分析碘基物质图中肺内血流灌注降低区的位置及数目,并测量肺内血流灌注降低区的碘基值及CT值,同时测量同层面或邻近层面正常肺实质的碘基值及CT值。混合能量图像与最佳单能量图像对栓子检出的数量比较采用卡方检验,血流灌注减低区与正常区域碘基值、CT值比较采用两样本秩和检验。结果:明确诊断肺动脉栓塞12例,采用混合能量图像观察发现栓子256个,其中中心型栓子(肺动脉主干、肺叶栓子)22个,外周型(肺段、肺亚段栓子)234个;完全闭塞型栓子58个,非完全闭塞型栓子198个。采用最佳单能量图像观察发现栓子273个,其中中心型栓子(肺动脉主干、肺叶栓子)22个,外周型(肺段、肺亚段栓子)251个;完全闭塞型栓子74个,非完全闭塞型栓子199个。最佳单能量图像在诊断外周型及完全闭塞型栓子较混合能量图像能增加检出数量,但两组比较差异无统计学意义(P>0.05)。肺内血流灌注减低区42处,血流灌注减低区((2.70±1.81)100μg/mm3、(-829±45.94)HU)与正常区域肺野((17.78±3.29)100μg/mm3、(-741±34.34)HU)碘基值、CT值比较,差异有统计学意(P<0.05)。结论:能谱CT对肺栓塞能进行定性和定位诊断,碘基物质图能够评价肺血流灌注变化,为评估肺栓塞病情提供信息。
    Abstract: Objective: To investigate the value of energy spectral CT in the diagnosis of acute pulmonary embolism and pulmonary perfusion changes. Methods: A retrospective analysis of 43 cases of suspected acute pulmonary embolism from November 2017 to July 2019, all patients with suspected acute pulmonary embolism underwent enhanced spectrum scanning, and the original data images reconstructed pulmonary angiography images and iodine-based substances at the workstation. Observe and record the location and number of pulmonary emboli; analyze the location and number of intrapulmonary perfusion reduction zone in the iodine-based substance map, and measure the iodine value and CT value of the intra-poor hypoperfusion zone, and measure the normal lung of the same level or adjacent level Substantial iodine value and CT value. The chi-square test was used to compare the number of emboli detected by the mixed energy image with the best single-energy image. The two-sample rank sum test was used to compare the iodine value and CT value between the perfusion reduction zone and the normal zone. RESULTS: A total of 12 patients with pulmonary embolism were diagnosed. A total of 256 emboli were found by mixed energy imaging. Among them, 22 were central emboli (pulmonary trunk and lobes), and peripheral type (pulmonary and lung sub-emboli) 234. There were 58 fully occluded emboli and 198 non-completely occluded emboli. A total of 273 emboli were found by the best single-energy image observation, including 22 central emboli (pulmonary trunk and lobes) and 251 peripheral (pulmonary and pulmonary emboli); fully occluded embolus 74, 199 non-completely occluded emboli. The best single-energy image had a higher detection rate than the mixed energy image in the diagnosis of peripheral and fully occluded emboli, but the difference was not statistically significant (P>0.05). The intrapulmonary perfusion reduction area was 42, the perfusion reduction area ((2.70±1.81) 100ug/mm3, (-829±45.94) HU) and the normal area lung field ((17.78±3.29) 100ug/mm3, (-741±34.34) HU) iodine value, CT value for comparison, the difference was statistically significant (P<0.05). Conclusion: Energy spectral CT can be used for qualitative and local diagnosis of pulmonary embolism. Iodine-based substance map can evaluate pulmonary blood perfusion changes and provide information for evaluating pulmonary embolism.
  • 期刊类型引用(10)

    1. 刘动,林沛元,李伟科,黄胜,马保松. 跨孔CT岩溶识别方法准确性的统计学评价. 岩土力学. 2024(03): 822-834+926 . 百度学术
    2. Dao-han Liu,Lei Wang,Lei Liu,Jun-jie Xu,Jian-qiang Wu,Pan Liu. Application of geophysical methods in fine detection of urban concealed karst: A case study of Wuhan City, China. China Geology. 2024(03): 517-532 . 必应学术
    3. 王瑞芳. 综合勘探方法在湖底岩溶区隧道的应用. 重庆建筑. 2023(01): 61-64 . 百度学术
    4. 彭军,李期佳,高建华,王鹏,熊友亮. 电磁波CT技术在城市隧道岩溶勘查工程中的应用. CT理论与应用研究. 2023(04): 471-479 . 本站查看
    5. 郑军. 井间电磁波CT不同初始模型成像效果对比. 工程地球物理学报. 2022(06): 868-876 . 百度学术
    6. 刘剑. 电磁波CT在既有铁路路基塌陷精细探测中的应用. 工程地球物理学报. 2021(05): 555-560 . 百度学术
    7. 王薇,邓小虎,金聪,周红伟,林松. 电磁波CT揭露重大工程岩溶发育特征——以某地铁岩溶勘察为例. 科学技术与工程. 2020(34): 13977-13982 . 百度学术
    8. 罗安华. 高密度电法在地下暗河探测中的应用——以石林诗玛溶洞为例. 科学技术与工程. 2019(27): 81-87 . 百度学术
    9. 黄生根,刘东军,胡永健. 电磁波CT技术探测溶洞的模拟分析与应用研究. 岩土力学. 2018(S1): 544-550 . 百度学术
    10. 罗日春. 电磁波CT技术在岩溶勘探中的应用与研究. 勘察科学技术. 2018(S1): 107-110 . 百度学术

    其他类型引用(1)

计量
  • 文章访问数:  349
  • HTML全文浏览量:  6
  • PDF下载量:  11
  • 被引次数: 11
出版历程
  • 收稿日期:  2019-07-18
  • 网络出版日期:  2021-11-07
  • 发布日期:  2019-12-24

目录

    /

    返回文章
    返回
    x 关闭 永久关闭